3. Parameter Address Map (Model ID = 42H)
This map indicates address, size, Data (range), Parameter, Description, and Default Value of parameters which can be transferred using and "Data set 1 (DT1)."
All the numbers of address, size, Data, and Default Value are indicated in 7-bit Hexadecimal-form.
■Address Block map
An outlined address map of the Exclusive Communication is as follows;
Address (H)
Block
40 00 00
+—————————————————————————+

| SYSTEM PARAMETERS

40 01 3F
+—————————————————————————+
40 1x 00
+—————————————————————————+
| PART PARAMETERS
|
(x = 0-F)
40 2x 5A
+—————————————————————————+
41 m0 00
+—————————————————————————+
| SRUM SETUP PARAMETERS
|
(m = 0-1)
41 m8 7F
+—————————————————————————+
48 00 00
+—————————————————————————+
| SYSTEM PARAMETERS
48 01 10
+—————————————————————————+
| PART PARAMETERS
48 1D 0F
+—————————————————————————+
49 m0 00
+—————————————————————————+
| DRUM SETUP PARAMETER
|
(m = 0-1)
49 mE 17
+—————————————————————————+
There are two ways in which GS data is transmitted: Individual Parameter Transmission in which individual parameters are transmitted one by one, and Bulk Dump Transmission in which a
large amount of data is transmitted at once.
■Individual Parameters
Individual Parameter Transmission transmits data (or requests data) for one parameter as one exclusive message (one packet of "F0 ..... F7").
In Individual Parameter Transmission, you must use the Address and Size listed in the following "Parameter Address Map." Addresses marked at "#" cannot be used as starting addresses.
●System Parameters
Parameters related to the system of the device are called System Parameters.
Address (H)
Size (H)
40 00 00
00 00 04
40 00 01#
40 00 02#
40 00 03#
* Refer to section 4. Supplementary material, "About tuning" (p. 15).
40 00 04
00 00 01
40 00 05
00 00 01
40 00 06
00 00 01
40 00 7F
00 00 01
* Refer to "System exclusive messages related to mode settings" (p. 5).
40 01 10
00 00 10
40 01 11#
40 01 12#
40 01 13#
40 01 14#
40 01 15#
40 01 16#
40 01 17#
40 01 18#
40 01 19#
40 01 1A#
40 01 :#
40 01 1F#
* The sum total of voices in the voice reserve function must be equal to or less than the number of the maximum polyphony. The maximum polyphony of this instrument is 128. For
compatibility with other GS models, it is recommended that the maximum polyphony be equal or less than 24.
|
Individual
|
Individual
|
|
Individual
|
|
Bulk
|
Bulk
|
Bulk
|
Data (H)
Parameter
0018-07E8
MASTER TUNE
Use nibblized data.
00-7F
MASTER VOLUME
28-58
MASTER KEY-SHIFT
01-7F
MASTER PAN
00
MODE SET
00-40
VOICE RESERVE
Description
Default Value (H)
-100.0 - +100.0 [cent]
00 04 00 00
0-127
7F
-24 - +24 [semitones]
40
-63 (LEFT) - +63 (RIGHT)
40
00 = GS Reset,
127 = Exit GS mode(Rx. only)
Part 10 (Drum Part)
02
Part 1
06
Part 2
02
Part 3
02
Part 4
02
Part 5
02
Part 6
02
Part 7
02
Part 8
02
Part 9
02
Part 11
00
:
Part 16
00
Description
0 [cent]
127
(= F0 7F 7F 04 01 00 vv F7)
0 [semitones]
0 (CENTER)
2
6
2
2
2
2
2
2
2
2
0
0
9

Advertisement

Table of Contents