<RefreshRate update_rate = "time" archive_rate = "time"
file_loc = "path"/>
update_rate is the refresh rate in minutes. Avoid values <10.
archive_rate is the rate at which archived reports expire from the system, that
is, the time in minutes that a recently accessed report will be maintained on the
system. The recommended minimum is five minutes. Archive_rate should be
greater than update_rate.
file_loc is the location of the files gathered and archived to support Re-
freshRate. Enter a valid, existing directory. This repository may need to be
very large if you expect many users to log on at the same time.
Example: The refresh rate for updates is set to ten minutes and the archive rate for
archived reports is set to thirty minutes.
<RefreshRate update_rate = "10" archive_rate = "30" file_loc
= "d:/tmp/"/>

Gauge Settings

System gauges display Data Protector system health graphically using a gauge with
three ranges: green, yellow, and red, indicating the protection status.
You can change the default settings to reflect the sensitivity of your data or the critical
nature of systems you are backing up.
To set the gauges, edit the line:
<BackupGauge green_band = "range" yellow_band = "range"
red_band = "range"/>
Example:
<BackupGauge green_band = "0-60" yellow_band = "60-80"
red_band = "80-100"/>
Do not allow color bands to overlap. If you change green to 0-70, you must also
change the lower value of yellow to 70.
NOTE:
Gauge settings in ConfigSpec.xml are applied to your entire system. If you want
some settings to be specific to a given module view, see
"Editing the Data Protector protection status
change the bands for each gauge that you create.
module" on page 44. You can still