Action
7.
Insert Code Floppy #2 when
prompted, press
Install the hard disk and continue
8.
Install the replacement hard
disk(s).
Enter
9.
Press
Enter
10. @DSKTST
PB60014–01
Octel Overture 200/300 Description and Response
The following message is printed.
Enter
CPU
486
Testing Processor...PASSED
Testing System Voltage/Temp...PASSED
Testing ROM Checksum...PASSED
Testing PIT...PASSED
Testing DMA...PASSED
Testing UART...PASSED
Testing Modem...PASSED
Testing TDM Crosspoint...PASSED
Testing Floppy...PASSED
Testing RTC...PASSED
Testing BIC...PASSED
Testing OCC...PASSED
Testing WDT...PASSED
Testing Control Bus Interface...PASSED
Testing COMPLETED
Booting from floppy disk file XBOOT.IM
Image loaded
Loading Image from Floppy Disk
Loading file VMS1_2.IM
Please insert code floppy #2 & Press Return..
Loading file VMS2_2.IM
Image loaded
–––––– SYSTEM SOFTWARE RELEASE S.X.X.X (XX/XX/XX) ––––––
Copyright(c) 199X Octel Communications Corp.
All Rights Reserved.
TUE 11/08 08:44:58
(Modem enabled)
@WAITING FOR VCU READY
SYSTEM INITIALIZATION SUSPENDED!
At this point the Octel Overture 200/300 has completely booted from
floppy diskette.
Refer to the Hardware Replacement chapter in this volume. Hard disks
may be hot plugged.
.
To log on to the Octel Overture 200/300.
At the @ prompt enter the slot number for the replaced drive. The VCU
tests the slot and updates its status record.
Repeat DSKTST for each drive to be replaced.
Model 300–6039–001
Step 27
19XX
ID:
S/N:000000
Last Logon : 00/00 00:00
Octel Overture 200/300
Procedures
12-55
Rev 02F
12MB
PBX:00
Serenade 3.0