Kmd-850Mrh (Remote Air-Cooled) - Hoshizaki KMD-850MAH Service Manual

Modular crescent cuber
Hide thumbs Also See for KMD-850MAH:
Table of Contents

Advertisement

3. KMD-850MRH (remote air-cooled)

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
CONDENSER VOLUME
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
833
70/21
80/27
803
90/32
793
100/38
782
70/21
80/27
90/32
100/38
70/21
280
80/27
248
90/32
238
100/38
190
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
205
80/27
219
90/32
223
100/38
229
70/21
38
80/27
40
90/32
41
100/38
43
35
WATER TEMP. (ºF/ºC)
50/10
70/21
378
793
364
741
360
698
355
685
1490
1513
1508
1544
1513
1570
1517
1576
1.06
238
0.94
182
0.90
136
0.72
134
18
19
18
20
19
22
19
22
2.9
2.6
2.7
2.3
2.6
2.0
2.4
2.0
14.4
223
15.4
248
15.7
268
16.1
274
2.7
41
2.8
44
2.9
47
3.0
49
11,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
1,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
121 CU. IN (URC-9F)
90/32
360
738
335
336
686
311
317
641
291
311
589
267
1541
1569
1596
1620
0.90
218
0.82
0.69
183
0.69
0.52
127
0.48
0.51
120
0.45
21
23
24
26
2.5
2.4
2.0
2.0
15.7
250
17.6
17.4
275
19.3
18.8
296
20.8
19.3
321
22.6
2.9
47
3.3
3.1
53
3.7
3.3
55
3.9
3.4
62
4.4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmd-850mwhKmd-850mrh

Table of Contents