6) Blow the icemaker water supply line out using the compressed air or carbon dioxide
supply.
7) Close the icemaker water supply line drain valve.
3. Drain the water tank:
1) Turn off the power supply.
2) Move the control switch to the "OFF" position.
3) Remove the insulation panel. Remove cube guide B, then remove cube guide A.
Remove the overflow cap, overflow pipe, and water shield. See Fig. 7.
4) Remove the drain plug.
5) Remove all ice from the storage bin/dispenser unit. Clean the storage bin/dispenser unit
using a neutral cleaner. Rinse thoroughly after cleaning.
6) Replace the drain plug, water shield, overflow pipe, overflow cap, cube guide A, cube
guide B, and insulation panel in their correct positions. Be careful not to cross thread
the drain plug or overflow pipe.
7) Replace the front panel in its correct position.