5-13. Connecting 1-Phase Input Power For 115 VAC Input

1
2
!
Installation must meet all National
and Local Codes − have only
qualified
persons
make
installation.
!
Always connect green or green/
yellow
conductor
to
grounding terminal first, and never
to a line terminal.
For 115 volts AC input power, a 20 ampere
individual branch circuit protected by
time-delay fuses or circuit breaker is
required.
1
Multi-Voltage Plug And Power Cord
Connector (NEMA Type 5−15P Plug
Shown)
For multi−voltage plug connections, see
Section 5-11.
2
Receptacle − NEMA Type 5−15R
(Customer Supplied)
Ref. 250 332-A
OM-249 498 Page 23