SX-6-26A AND SX-6A

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents .
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com .
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice .
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 66-1000
Fax: (570) 66-90
Part # 451558 (02/29/08)
Part # 4515558 (02/29/08)
APPLIANCE
WARNING:
GARLAND COMMERCIAL RANGES, LTD .
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE .
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED .
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas . This
information shall be obtained by consulting
your local gas supplier .
Enodis UK LTD .
Swallowfi eld Way, Hayes, Middlesex UB 1DQ ENGLAND
Telephone: 081-561-04
Fax: 081-848-0041
© 2005 Garland Commercial Industries, Inc .
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Sunfire SX-6-26A

  • Page 1: For Your Safety

    INSTALLATION AND OPERATION MANUAL SUNFIRE GAS RESTAURANT RANGE MODELS SX-6-26A AND SX-6A FOR YOUR SAFETY: PLEASE READ ALL SECTIONS OF THIS MANUAL DO NOT STORE OR USE GASOLINE AND RETAIN FOR FUTURE REFERENCE . OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF...
  • Page 2 Page 2 Part # 4515558 (02/29/08)
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DIMENSIONS AND SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INTRODUCTION .
  • Page 4: Dimensions And Specifications

    DIMENSIONS AND SPECIFICATIONS Shipping Information Mode Total Description Number BTU/Hr Lbs. Cube SX-6-26A Six Open Burners w/26" Oven 162,000 8 .0 SX-6A Six Open Burners w/open storage 12,000 8 .0 Height Oven Interior Combustible Wall Clearance Width Depth w/Legs w/o Legs...
  • Page 5: Introduction

    DIMENSIONS AND SPECIFICATIONS, Continued GAS PRESSURES Minimum Supply Gas Pressure Operating Pressure Natural Gas: 1 .12 kPa . Natural Gas: 1 .0 kPa . Propane: 2 .75 kPa . Propane: 2 .75 kPa . NOMINAL GAS CONSUMPTION AND INJECTOR SIZE Natural Gas Propane Gas INJ .
  • Page 6: Installation

    INSTALLATION Clearances  . Securely fasten the support brackets to the burner box sides with (4) #14 x 5/8 Hex washer head, type B tapping screws . (Hardware package is supplied) . Construction Sides Rear Combustible 9” (20 mm) 6” (152 mm) Non-combustible 0 mm 0 mm...
  • Page 7: Gas Connection

    INSTALLATION Continued This appliance must be installed in accordance with the “ALL DOWNSTREAM BURNER AND PILOT VALVES MUST manufacturer’s instructions, local gas fitting regulations and BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE requirements of the A .G .A . 601 Installation Code . All burner SUPPLY .
  • Page 8: Adjustments

    TESTING & ADJUSTMENT Continued 4 . Check pilot flame on installation . If pilot adjustment is 1 . Check operation and adjust as below to provide a sharp required at any time, please ensure the pilot adjustment blue flame at full rate . screw is sealed and there are no leaks .
  • Page 9: Operation

    OPERATION Open Top Burners Standard Ovens Lighting: Lighting: 1 . Open 1/4 turn pilot isolation valves . 1 . Remove oven bottom(s) . 2 . Light pilots . 2 . Depress and hold the red reset button, located on the safety valve behind the kick panel below the oven door,  .
  • Page 10: Maintenance & Cleaning

    MAINTENANCE & CLEANING Exterior Finish Oven Interior (Porcelain Enamel) Establish a regular cleaning schedule . Any spills should be NOTE: Disconnect line cord (if applicable) from power wiped off immediately . supply before cleaning or servicing . The oven should be permitted to cool down before cleaning 1 .