6-5. Control Board PC1 Test Point Values (115 VAC Model)

a) Tolerance − 10% unless specified
Receptacle
Pin
RC1
1
2
3,4
5
6
7
8
RC2
1
2
3
4
RC4
−−
RC5
−−
TP
A
TP
B
TP
C
TP
D
TP
E
TP
F
Handler 135 / 175
PC1 Voltage Readings
Voltage Readings:
24 volts ac input, reference to pin RC1-2
24 volts ac input, reference to pin RC1-1
35 volts dc with transformer thermostat closed, reference to pin TP-C
35 volts dc with gun trigger closed, reference to TP-C
35 volts dc, reference to TP-C
15.0 volts dc, reference to TP-C
15.0 to 6.5 volts dc from min to max of Wire Feed speed control R1, Reference for TP-C
Negative (−) welder output voltage
Not used
Positive (+) output to wire drive motor
Negative (−) output to wire drive motor
Circuit common
Positive (+) welder output voltage with gun trigger closed
35 volts dc, reference to TP-C
15 volts dc, reference to TP-C
Circuit common
30 volts dc, reference to TP-C
15 volts dc with Wire Speed control R1 at minimum, reference to TP-C
11 volts dc with Wire Speed control R1 at maximum, reference to TP-C
Return To Table Of Contents
a) Tolerance
specified
b) Reference − to circuit common
unless noted
b) Reference − as noted
Value
10%
unless
TM-944 Page 27