Heat & Glo SLR32 Owner's Manual
Hide thumbs Also See for SLR32:
Table of Contents

Advertisement

Model:
SLR32
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13
Owner's Manual
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SLR32

  • Page 1 Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 3: Table Of Contents

    E. Junction Box Installation......48 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 4 D. Contact Information ......70  = Contains updated information. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 9: User Guide

    - A decorative fi rescreen. - Adjustable safety gate. DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.F. CLEAR SPACE SECTION 2.C. Figure 2.1 General Operating Parts Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 10: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 12: After Fireplace Is Lit

    Wall above appliance feels hot to No action necessary. This appliance ships with a non-combustible material attached. Specifi ca- the touch. tions of the attached non-combustible material are listed in Section 1.E. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 13: Maintenance And Service

    - Heavy deposits: Use commercial fireplace glass cleaner (consult with your dealer) • Refer to Section 14.F for glass removal and replacement instructions. • Reinstall door or decorative front. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    Tools needed: Protective gloves, vacuum cleaner, dust cloths • Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that Figure 3.1 IPI Pilot Flame Pattern Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 15: Installer Guide

    CEILING FIRESTOP ON FLOOR OF ATTIC (SECTION 8.C) FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) FRAMING/HEADER (SECTION 5) WALL SWITCH GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 16: Design And Installation Considerations

    Electric drill and bits (1/4 in. magnetic) Plumb line Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 17: Framing And Clearances

    TOP VENT ONE 90 ELBOW TOP VENT ONE 90° ELBOW Inches 46-3/4 37-5/8 63-1/8 15-1/16 18-3/4 See Section D. Figure 5.5 & 5.6 Millimeters 1188 1603 Figure 5.1 Appliance Locations Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 18: Constructing The Appliance Chase

    Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 19: Clearances

    Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) Inches 8-5/8 36-1/2 18-1/4 37-3/4 Millimeters Figure 5.2. Clearances to Combustibles Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 20: Mantel And Wall Projections

    NAILING TAB 1/2 IN. FACTORY-SUPPLIED NON-COMBUSTIBLE BOARD Note: For non-combustible fi replace fi nish material (marble, stone, etc) specifi cations refer to Section 13.C. Figure 5.7 Front Side Finishing Detail Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 21 1/2 IN. THICK WALL 5 IN. SHEATHING NON-COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 1 IN. 1 IN. AIR SPACE Figure 5.8 Non-Combustible Zone Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 22: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 23 2 sides beneath the fl oor. venting system does not meet these requirements. • Vinyl protection kits are suggested for use with vinyl siding. Figure 6.3 Minimum Clearances for Termination Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 24: Vent Information And Diagrams

    • When penetrating a combustible ceiling, a ceiling fi restop must be installed. Horizontal • Horizontal runs of vent do not require vertical rise; Figure 7.1 horizontal runs may be level. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 25 2.1 m (see Figure 7.3). 4 ft. 1.2 m 14 ft. 4.3 m H MAX. =14 ft. (4.3 m) V + H MAX. = 40 ft. (12.2 m) Figure 7.4 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 26 15 ft. 4.6 m (see Figure 7.3). H + H MAX. =15 ft. (4.6 m) V + H + H MAX. = 40 ft. (12.2 m) INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 27 MAX. =14 ft. (4.3 m) (see Figure 7.3). MAX. = 40 ft. (12.2 m) *No specifi c restrictions on this value EXCEPT V + H cannot exceed 40 ft. (12.2 m) Figure 7.6 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 28 fl ame height. If the vent confi guration has a total ver- tical of 15-44 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 29 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.10 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 30 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). INSTALLED HORIZONTALLY Figure 7.11 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 31 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3). Figure 7.12 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 32 CAUTION! DO NOT use any fl ue restrictor when vent- ing with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may result in poor fl ame appearance, sooting, pilot malfunction, or overheating. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 33: Top Vent

    VENT PIPE EXISTING CHIMNEY To minimize cold air drafts, seal with non-combustible insulation. DIRECT VENT FIREPLACE Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m HEARTH FLOOR Figure 7.15 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 34: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 35: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 36: Install Attic Insulation Shield

    • Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 37: Appliance Preparation

    For all venting applications, ensure that the pipe gasket is in place before attaching any pipe section. This gasket is shipped in place around the starting collar. See Figure 9.1. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 38: Securing And Leveling The Appliance

    Figure 9.2 shows the fireplace installed on the floor. However, this fireplace can be elevated off the floor provided that the fi replace is properly supported by framing materials and the ceiling clearances are maintained. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 39: Installing Vent Pipe (Slp Pipe)

    Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 40: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 41: Disassemble Vent Sections

    1/8 in. (3 mm) larger than the support box outline. • Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 42: Install Metal Roof Flashing

    • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Figure 10.14 Assembling the Storm Collar Around the Pipe Figure 10.14 Assembling the Storm Collar Around the Pipe Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 43: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.16. Figure 10.16 Wall Thimble Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 44: Install Horizontal Termination Cap

    1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 10.17 Venting through the wall Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 45: Gas Information

    Figure 11.3. Remove Valve Plate 4. Lift the valve assembly up and out to make necessary plate as well as valve bracket screw. See Figure 11.2 service or repair. and Figure 11.5. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 46: Gas Connection

    fi replace when valve assembly is installed. • In CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 47: Electrical Information

    fi rebox bottom. DC ADAPTER JUNCTION BOX THERMOSTAT WIRE THERMOSTAT WIRE CONTROL MODULE VALVE BATTERY PACK (LOCATED INSIDE BOTTOM COVER PANEL) Figure 12.1 Valve Cavity Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 48: Electrical Service And Repair

    6. Reinstall the junction box. 7. Reposition the junction box heat shield such that it is positioned over the junction box. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 49: Finishing

    NON-COMBUSTIBLE BOARD rial. Ensure that the 1 inch air space clearance is main- tained on the sides of the fi replace. See Figure 13.2. Figure 13.2 Front Side Finishing Detail Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 50 Note: Refer to Section 13.C regarding installation details associated with the Inside and Overlap Fit methods. The SLR32 must be fi nished using either the Tonic or Martini decorative fronts. See Figures 13.12 and 13.13. The fi nal fi replace installation can be accomplished by either the Overlap Fit or Inside Fit method.
  • Page 51 12 inch intervals along the joint length. • The wall-board joints should be fi nished with a Taping Coat, followed by at least two subsequent Finish Coats of joint compound. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 52: Mantel And Wall Projections

    (Acceptable on both sides of opening) 14 IN. MIN. MEASUREMENT FROM TOP OF FIREPLACE OPENING 1 IN.MIN. 4 IN. MAX. Figure 13.6 Clearances To Non-Combustible Mantels Or Other Non-Combustibles Above Appliance Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 53: Facing Material

    FINISHING MATERIAL 0-1 IN. THICK TONIC DECORATIVE FRONT SHOWN NON-COMBUSTIBLE FINISHING MATERIAL 0-1 IN. THICK DRYWALL OR EQUIVALENT (1/2 IN.) Figure 13.9 Overlap Fit Method (Tonic or Martini Decorative Front) Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 54 Only) 0-4 IN. 3/4 IN. 20-1/2 IN. APPLIANCE OPENING (HEIGHT) 3 IN. 0- 4 IN. DRYWALL OR EQUIVALENT (1/2 IN.) Figure 13.10 Inside Fit Method (Tonic Decorative Front Only) Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 55: Decorative Fronts

    Bottom of decorative front to bottom 8-3/8 IN. 212 mm of appliance. Outside dimension of decorative 34-3/16 IN. 868 mm front (width). Outside dimension of decorative 18-7/8 IN. 480 mm front (height). Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 56: Appliance Setup

    fi rebox. Blocking this gap may cause an undesirable fl ame appearance. See Figure 14.2. Figure 14.2. Maintain Media Tray Air Spaces. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 57 4. Install only approved media kit. Options include: • MEDIA-AMBER • MEDIA-BLACK • MEDIA-CLEAR • MEDIA-COBALT • MEDIA-BK2-GEMS • MEDIA-WH2-GEMS • MEDIA-STONES-2 • SLR32-LOGS • MEDIA-CL2-GEMS • GLASS32-LINER Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 58: Fixed Glass Assembly

    Air Shutter Settings SLR32 Glass Rock Media 1/8 in. 1/4 in. Media Stones (Optional Kit) Logs (Optional Kit) 3/16 in. 5/16 in. Table 14.1 Figure 14.4 Fixed Glass Assembly Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 59: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 60 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 61: Reference Materials

    Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. I Ø Location Inches Millimeters Location Inches Millimeters 12-7/8 27-1/4 25-3/4 7-1/4 36-3/4 7-1/2 3-1/2 8-1/4 2-1/4 39-3/4 1010 9-3/4 6-5/8 25-3/4 18-5/16 Figure 16.1 Appliance Dimensions Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 62: Vent Components Diagrams

    (292 mm) (352 mm) 12-1/4 in. (311 mm) 16 in. (406 mm) PVK-80 DVP-BEK2 (For use with IPI and DSI appliances only.) DVP-HPC Cap Brick Extension Figure 16.2 Vent Components Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 63 8-11/16 in. 1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.3 SLP Series Vent Components Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 64 Vertical Termination Cap SLK-SNKD Snorkel Termination Cap 12 IN. 305 mm 7 IN. 178 mm 15-1/2 IN. 394 mm DVP-FBHT SLP90 SL-2DVP DVP-FBHT Figure 16.4 SLP Series Vent Components Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 65 (97 mm) 5-1/16 in. 2-5/16 in. 8 in. 14-7/16 in. (128 mm) 59 mm (203 mm) 367 mm SL-2DVP SLP-WT-BK Adapter Wall Thimble-Black Figure 16.5 SLP Series Vent Components Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 66: Coaxial To Colinear Venting

    SLP-LPC (318 mm) SLP Low Profi le Cap COAXIAL to COLINEAR VENTING LINK-DV30B DVP-2SL DV-46DVA-GCL Flex Liner Kit Adapter Coaxial/Colinear Appliance Connector Figure 16.6 Coaxial to Colinear Vent Components Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 67: Service Parts

    Glass Door Assembly SRV-GLA32 Lower Cover Panel 2269-103 Valve Assembly Refer to valve page Junction Box Bracket 2269-154 Junction Box 4021-013 Additional service part numbers appear on following page. 6/13 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 68 Jumper Wires 21 in 2012-206 10.13 3 Volt Transformer 593-593A 10.14 Battery Pack 593-594A 10.15 Module Wire Assembly 593-590A 10.16 Module 593-592 Additional service part numbers appear on following page. Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 69: Service Parts

    Touch Up Paint TUP-GBK-12 WSK-21-W Wall Switch Kit Conversion Kit NG Conversion Kit LP LPK-SLR32 Pilot Orifi ce NG 593-528 Pilot Orifi ce LP 593-527 Regulator NG NGK-DXF Regulator LP LPK-DXF Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...
  • Page 70: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2013 Heat & Glo • SLR32 • 2269-900 Rev. H • 6/13...

Table of Contents