Heat & Glo 6000TR-OAK Owner's Manual page 12

Installation and operation
Table of Contents

Advertisement

STRAIGHT UP
VERTICAL VENTING
V (FT.)
40' MAX. (12.4 M)
NOTE: On vertical venting
configurations over 10 feet
install the flue restrictor
(385-128). See flue restric-
tor installation instructions.
Figure 6.
Straight Up Vertical Venting
16
CAP
V
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06
Flue Restrictor Instructions
1. Remove Exhaust Shield using a 1/4" nut driver by
removing the four screws securing it in place (see
Figure 7).
EXHAUST
SHIELD
FLUE
RESTRICTOR
Figure 7
2. Break the Flue Restrictor into two pieces. Do this
by bending the part back and forth until it breaks
(see Figure 8).
BREAK
HERE
Figure 8.
Flue Restrictor