The P43 Pellet Stove has huge features in a small package, giving you 0 to 43,000 BTU when you need it,
automatically. You basically need to set your desired room temperature and fill the hopper. With the P43 you will
notice even heat throughout your zone and a level of convenience you never thought possible.
The P43 epitomizes the capability of Harman Pellet Stoves, taking advantage of Harman's 20+ years of pellet
stove design, technology and manufacturing. This 43,000 BTU stove has the smartest controls coupled with
minimal maintenance. The P43's output is managed by a microprocessor that senses the room temperature and
the fire temperature with tiny thermistor probes and then determines the best feed rate for your heating demand.
This improved and smarter control also has a diagnostic port which allows a service representative to attach an
external display showing live working data for ease in troubleshooting.
The platinum combination is Harman's Patented Feeder & Burn Pot, and ESP Control which have been developed
to their highest state. These features work together to allow amazing heat output with little regard for fuel quality.
This label is located on the back of the unit.
Please copy the Serial Number for future reference.
Serial #:
Harman PP38+/P43 Pellet Stove
Label measures: 4-3/8" high X 10-3/4"wide
Black Background with bare metal for print-adhesive backed, metal plate.
MODEL / MODÈLE:
"PP38+ /
P43"
Room Heater Pellet Fuel Burning Type. Also for use in Mobile Homes.
Appareil de chauffage à granulés de bois Utilisable dans des mobile homes.
This pellet burning appliance has been tested and listed for use in Manufactured
Homes in accordance with OAR 814-23-900 through 814-23-909
Report #/ Raport # 135-S-21-6.2 (PP38+)
Report #/ Raport # 135-S-23b-6.2 (P43)
Serial No.
008
Tested to / Testé à:
BARCODE LABEL
N
de série:
o
ASTM E1509-04, ULC/ORD-C1482-
M1990, ULC-S627-00
MINIMUM CLEARANCES TO COMBUSTIBLES/
"PREVENT HOUSE FIRES"
DISTANCES DE SECURITE PAR RAPPORT AUX
Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions.
MATERIAUX COMBUSTIBLES:
WITHOUT
Contact Local Building or Fire Offi cials About Restrictions and Installation Inspection in Your Area.
SIDE SHIELDS
Sans Écrans
WARNING : THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,
Latéraux
AND CEILING/ROOF MUST BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.
Back Wall / Entre Mur Arrière
2"/ 51mm
An outside combustion air inlet must be provided. Refer to Manufacturer's instructions and local
Side Wall / Entre Paroi Latér
16"/ 406mm
codes regarding the requirements for passing the exhaust venting system through a combustible
CORNER INSTALLATION / EN ANGLE
wall or ceiling.
Walls to Appliance
9"/228mm
Entre Murs et appareil
Inspect and Clean Exhaust Venting System Frequently.
Flue Connector/Raccord à la cheminée
Use a 3" or 4" diameter type "L" or "PL" venting system.
FLOOR PROTECTION / Protection Du Plancher
Do Not Connect This Unit to a Chimney Flue Serving Another Appliance.
USA
Canada
FOR USE WITH WOOD PELLET FUEL OR UP TO 50% CORN / PELLET MIXTURE ONLY.
Sides*/Côtés (A)
6"
200mm
The Use of Other Fuels May Create an Unsafe Condition.
Back**/Arrière (B)
6"
200mm
Input Rating Max: 5.5 lb. fuel/hr.
Front*/Avant (C)
6"
450mm
**Measured from pedestal base in the US ONLY
U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPS
**Mesuré à partir de la base du socle aux États-Unis uniquement
Route Power Cord Away From Unit.
*Measured from Glass Opening
*Mesurer à partir de la surface de la porte en verre
DANGER: Risk of Electrical Shock. Disconnect Power Before Servicing Unit.
Floor Protection Must Be a Non-Combustible Material.
For Further Instruction, Refer To Owner's Manual.
Must Also be Place Under Any Horizontal Flue Connector,
Replace glass only with 5mm ceramic available from your dealer.
Extending 2" or 51mm Beyond the Pipe Measurement.
Pour protéger le plancher, il faut sous le pêole un matériau. Qui
Keep Viewing and Ash Removal Doors Tightly Closed During Operation.
doit aussi être placé sous les parties horizontales du tuyau de
raccord à la cheminée et s'étendre à 51mm o 2 po. au-delà de
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
la mesure du tuyau.
Safety listing: Omni-test laboratories, inc.
tested to: ASTM E1509-04, ULC S627-00, and
ULC/ORD-C1482-M1990. Report #135-S-23b-6.2
This appliance is also approved for installation into a
shop.
Division of Hearth & Home Technologies, Inc
352 Mountain House Road
Halifax, PA 17032
4
P43 Pellet Stove
introduction
"PREVENTION DES INCENDIES"
Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignes
de fonctionnement. Respecter les règles de sécuritè en vigueur dans votre région.
Made in U.S.A. of US and imported parts. / Fabriqué
AVERTISSEMENT POUR MOBILE HOMES: Ne pas installer dans une chambre. ll est imperatif
aux États-Unis-d'Amérique par des pièces d'origine
de prévoir une prise d'alr extérieur. L'intégrité structurale du plancher, du plafond et des murs doit étre
américaine et pièces importées.
strictement préservée. Se reporter aux instructions du fabricant et aux réglementations spécifi ques
locales concernant les précautions requises lors de la traversée d'un mur ou d'un plafond.
2"(51mm)
Contróler et nettoyer fréquemment tout le systeme d'evacuation des fumées conformément aux
recommandations du constructeur. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou
102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà utilisé pour un autre appareil.
FONCTIONNE EXCLUSIVEMENT AVEC DES GRANULES DE BOIS.
Appareil de chauffage à granulé type. Consommation maximum: 2.5 kg/h.
US coupure: 115 VAC, 60 Hz, 4.2 amps Démarrer, Exécuter 2.8 AMPS
WITH
fonctionnement normal 1.1A. Tenir le cordon d'alimentation à l'écart du poèle.
SIDE SHIELDS
DANGER: Risque d'électrocution. Débrancher l'appareil avant toute intervention.
Avec Écrans
10" (254mm) with side shields
Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme qualité disponible
Latéraux
16" (406mm) w/out side shields
auprès de votre revendeur.
2"/ 51mm
Pour une information plus compléte, se reporter à la notice d'utilisation. Tenir la porte
10"/ 254mm
76mm min
hermétiquement close durant fonctionnement.
3" min
9"(228mm)
Ne faites pas obstacle l'espace sous le réchauffeur. Toujours fournir un approvisionnement suffi sant en air frais
jusqu'au lieu d'installation Appliance
9"/228mm
3" /76mm
US ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certifi cation under 40 CFR 60.531
by defi nition [Wood Heater (A) "Air-to-Fuel Ratio"]
PROtectiOn de SOl
Agence Américaine pour la Protection de l'Environnement
FlOOR PROtectiOn
Ce modéle est dispensé par EPA certifi cation d'aprés 40 CFR 60.531
par dèfi nition [Appareil á bois (A) << Ratio air/combustible>>]
b
Date of Manufacture / Date de fabrication:
2012 2013 2014 jan Feb MaR aPR MaY jun jul aug SeP Oct nOv dec
a
a
c
uSa
canada
F
loor protector
Fabriqué par: Harman Stove Company 352 Mountain House Road, Halifax PA 17032
P.N. 3-90-04300

table of contents

Safety Information
Specifications / Wiring Diagram
Rev c
Fuel Specification Details
Power Failure / Back-up
= contains updated information
5
6
8
15
16
19
21
22
27
28
29
30
32
33
35
3-90-04301R18_03/13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents