KitchenAid KEHS01P Use And Care Manual page 6

Kitchenaid front-loading electric dryer use & care guide kehs01p, ykehs01p
Hide thumbs Also See for KEHS01P:
Table of Contents

Advertisement

Available languages

Available languages

A sturdy floor to support the total dryer weight of 200 lbs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer. If slope is greater than 1 in. (2.5 cm), install
Extended Dryer Feet Kit, Part Number 279810. Clothes may
not tumble properly and automatic sensor cycles may not
operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18 in. (46 cm) above the floor. If using a pedestal, you
will need an additional 6 in. (15.24 cm).
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to fully open the dryer
door.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
Companion appliance spacing should also be considered.
Dryer Dimensions
*
½
*Most installations require a minimum 5½ in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
6
Minimum installation spacing for custom undercounter
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Dryer only
Minimum installation spacing for recessed or closet
installation, with or without a pedestal
Closet installation - Dryer only
½
Recessed or closet installation - Dryer on pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
"
"
"
"
½
"
1
1. Side view- closet or confined area
2. Closet door with vents
1
1. Recessed area
2. Side view - closet or confined area
"
in.
in.
"
2
½
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ykehs01p

Table of Contents