FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial You can find them on a label on the side of each unit. Dealer's Name Date Purchased • Staple your receipt to this page in the event you need to prove date of purchase or for warranty issues.
Page 3
Safety Precautions To prevent injury and property damage, follow these instructions. ;¢;_%y • Incorrect operation due to ignoring instructions may cause harm or damage, the seriousness of which is indicated by the following symbols. &CAUTION ,_W,8,,RN_NG This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only.
Page 4
Safety Precautions • Operation • Otherwise, it may cause • Doing so may cause electric • Doing so may cause electric electric shock or fire due to shock or fire due to heat shock or fire. heat generation. generation. • Doing so may cause electric •...
Page 5
Safety Precautions • Doing so may cause failure of machine or • It is not designed to cool the entire house. electric shock. • Installation • They are sharp and may • It may cause failure of • Using a damaged outer case cause injury.
Page 6
Safety Precautions • Operation • There is danger of fire or • Water may enter the unit and electric shock. degrade the insulation. It may also cause an electric shock. • Since the fan rotates at high • This could injure the pet or •...
Page 7
Priorto Operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, only replace it with an authorized replacement...
Page 8
Introduction This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. This symbol indicates special notes. AWARNING This appliance should be installed in accordance with the National Electric Code. VERTICAL A IRDEFLECTOR AIR FILTER (HORIZONTAL LOUVER)
Page 9
Electrical Safety 115V~ 230V- Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button.
Page 10
Electrical Safety IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED A. SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OCCASIONALLY: Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made.
Page 11
Installation NAME OF PARTS Curtain Curtain Frame Upper Guide Side Guide Support Bracket Bracket Leveling Bolt & Nut Bolt Washer Side Guide seal Foam Seal Strip Window Track Seal Window Locking Bracket Screw (Type A) Screw (Type B) Screw (Type C) For installation in a casement window, the 1.
Page 12
Installation 1. To prevent vibration and noise, make sure the unit is installed securely and firmly Awning Fence 2. Install the unit where the sunlight does not Cooled air shine directly on the unit. Heat radiation 3. The outside of the cabinet must extend outward for at least 14"...
Page 13
Installation 1. Loosely attach the Support Bracket to the bottom of Bracket using Bolts, Washer, and Bracket Nuts. Attach the Leveling Bolt and Nut. (Fig. Leveling Bolt & Nut Support 2. Remove protective backing from Window Track Seal and apply seal to window track. Fig.
Page 14
Installation 7. Measure height of window opening from top of Bracket assembly as shown Fig. 5. Subtract 20-3/4 inches. Mark this measurement on Curtain and cut the Curtain. (Fig. 5) Fig. 5 8. Slide Curtain into Curtain Frame. Slide Curtain Frame assembly into side Guides of the Air Conditioner cabinet.
Page 15
Installation seal strip Check all seals and plug any remaining air gaps with a suitable weatherproof caulk. 14. If this is a casement window installation, proceed to Casement Window Installation. If not, stuff the Foam Seal Strip between the vertical sash and the window glass. (Fig. 9) locking bracket 15.
Operating I nstructions A CAUTION When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to cooling mode again. OFF - Turns air conditioner off. High MEOFAN - Med speed fan operation without cooling.
Page 17
Operating I nstructions Additional controls and important information. The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is then opened and room air is exchanged with external air.
Page 18
Maintenance andService TURN T HE A IR CONDITIONER OFF AND REMOVE THE PLUG F ROM THE POWER OUTLET. The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. To remove: 1.
Page 19
Maintenance andService Before calling for service If you have problems with your air conditioner, read the following information try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer. Air conditioner does not operate 1.
Page 20
Maintenance andService The air conditioner may be operating abnormally when: • Make sure the plug is completely plugged into the outlet. • Check the fuse/circuit breaker box and replace the fuse or reset the breaker. • In the event of a power failure, set the The air power control to OFE When the power conditioner...
Page 21
FIRST YEAR ANY PART: If ally part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service.
Page 23
,,r#edTr#cn® FRIEDRICH AIR CONDITIONING Visit our web site at www.friedrich.com Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 P/NO.: 3828A20291P _Y.,[01 l ,,!_[0[0] [ _]...
Need help?
Do you have a question about the SV10A10A and is the answer not in the manual?
Questions and answers