Instructions
[_ Check
Ignition
of Surface
Burners
Operation of all cooktop burners should be checked after the
range and gas supply lines have been carefully checked for
leaks.
Electric Ignition
Select a top burner knob and simultaneously push in
and turn to LifE position. You will hear a clicking sound
indicating proper operation of the spark module. Once the air
has been purged from the supply lines, burners should light
within 4 seconds. After burner lights, rotate knob out of the
LITE position. Try each burner in succession until all burners
have been checked.
Read these instructions
completely
and carefully.
Quality
of Names
The combustion quality of burner flames needs to be
determined visually.
(AI Yellow flumes-
Call for service
(BI Yellow tips on
outer cones-
Normal for LP gas
(CISoft blue
flumes--Normal
fornatural g as
If burner flames look like (A),call for service.Normal burner
flames should look like (B)or (C), d epending on the type of gas
you use.
With LP gas, some yellow tipping on outer cones
is normal.
rg] Level
the Range
r_
Install the oven racks in the oven and position the range
where it will be installed.
Raise
range
(on some
models)
Rais_!_!i°wer
range
range
(on some models)
Z]
Checkfor levelness by placing a spirit level
or a cup, partially filled with water, on one
of the oven racks. If using a spirit level,take two
readings-with the level placed diagonally first in one
direction and then the other.
r-_ Remove the warming drawer. See the Care and cleaning
of the range section. The front leveling legs can be
adjusted from the bottom and the rear legs can be
adjusted from the top or the bottom.
[]
Use an open-end or adjustable wrench to adjust the
leveling legs until the range is level.
WARN
INGlnever comp,eteiy remove t heleveling
leg as the range will not be secured to the
anti-tip device properly.
[]
After leveling the unit, slide it into final position and verify
levelness.
After the range is level, slide the range away from the wall
so that the Anti-Tip device can be installed.