GE monogram ZIS420NXB Owner's Manual page 27

Side-by-side 36", 42", 48" built-in refrigerators

Advertisement

Performance
Data Sheet
SmartWater Filtration System
MWF Cartridge
This system
has been tested
according
to NSF/ANSI
42/53
for reduction
of the substances
listed
below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than
or equal
to the permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI
42/53.*
(100% safety factors built in for unmetered
usage)
USEPA
Influent
Parameter
MCL
Challenge Concentration
Chlorine
-
2.0mg/L± 10%
T&O
-
-
Particulate**
-
_> 10,000particles/mL
Standard No. 42: Aesthetic Effects
Influent
Effluent
Average
Average
Maximum
1.96mg/L
0.06mg/L
0.11mg/L
6,400,000 #/mL
58,833#/mL
150,000 #/mL
% Reduction
Average
Minimum
96.77%
94.74%
99.14%
97.97%
Min. Required
Reduction
> 50%
_> 85%
Parameter
Turbidity
Cysts
Asbestos
Leadat pH6,5
Leadat pH85
Mercuryat pH6.5
Mercuryat pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4 dichlorobenzene
Atrazine
USEPA
MCL
0.5 NTU
_> 99.95%Reduction
_> 99%Reduction
0,015mg/L
0,015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0,003mg/L
0.005mg/L
0,040mg/L
0,075mg/L
0.003mg/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11 + 1 NTU***
Minimum50,000L
107to 108fibers/L; > 10pm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
10,5 NTU
118,750 #/L
57 MF/L
0.1567 mg/L
0,1433 mg/L
0,0059 mg/L
0,0057 mg/L
0,0367 mg/L
0,0020 mg/L
0,2033 mg/L
0,0160 mg/L
0,0145 mg/L
0,0830 mg/L
0,2283 mg/L
0,0087 mg/L
Effluent
Average
0,14NTU
< 1 #/L
0,996MF/L
< 0,001mg/L
< 0,001mg/L
0,000350 mg/L
0,000325 mg/L
0,00023 mg/L
< 0.00002 mg/L
0,00337 mg/L
0,00100 mg/L
0.000500 mg/L
0,001000 mg/L
0.000500 mg/L
< 0,0005mg/L
Maximum
0.28NTU
4#/L
< 1 IVlF/L
<0.00t mg/L
<0.00t mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
< 0.00002 mg/L
0.011000 mg/L
0.001000 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
% Reduction
Average
Minimum
9854%
97.20%
> 99.99%
> 99.99%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
9934%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
9651%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93.33%
Min. Required
Reduction
0.5 NTU
_> 99.95%
_> 99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0,04mg/L
0.075mg/L
0.003mg/L
Tested using a flaw rate af 0.50 gpm; pressure af 60 psig; pHaf 7.5 +_0.5; temp. af 68 ° +_5°F (20° +_3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating
Specifications
[] Capacity: certified for up to 300 gallons (1135 I); up to one gear
[] Pressure requirement:
40-120
psi (2.8-8.2 bar), non-shock
[] Temperature:
33-100%
(0.6-38°0
[] Flow rate: 0.5 gpm (1.9 Ipm)
General
Installation/Operation/Maintenance
Requirements
[] Flush new cartridge
at full flow for 3 minutes to purge out trapped
air.
[] Replace cartridge
when the indicator
light flashes.
Special
Notices
[] Installation
instructions,
parts
and service
availability,
and standard
warranty
are included
with the product
when
shipped.
[] This drinking water system
must be maintained
according
to manufacturer's
instructions,
including replacement
of filter cartridges.
[] Do not use with water
that is microbiologicallg
unsafe
or of unknown
quality
without
adequate
disinfection
before
or
after the system.
Systems
certified
for cyst reduction
may be used on disinfected
water
that may contain
filterable
cysts.
[]The
contaminants
or other
substances
removed
or reduced
by this water
treatment
system
are not necessarily
in your water.
[] Check for compliance
with the state
and local laws and regulations.
[] Note that while the testing
was performed
under
standard
laboratory
conditions,
actual
performance
may vary. Systems
must
be
installed
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbiditg Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY40225
EPAEST.No. 070595-MN-001
27