Knoll IR100 Installation Instructions

Tabletop infrared receiver

Advertisement

Quick Links

IR100 Infrared Receiver Specifications:
Specifications
Infrared carrier frequency: 30-60kHz
Indoor reception range:
Nominal reception angle:
Maximum wire length:
Wire requirements:
Power requirements:
Dimensions:
Requires 12VDC power supply, emitter(s) and IR54, or
IR55 connection block.
Warranty
Knoll Systems warrants its products sold in the USA and Canada by authorized
Knoll dealers to be free of defects in materials and workmanship. This warranty
extends for three full years from the date of purchase by the original consumer.
Any products returned to Knoll Systems and found to be defective by Knoll
Systems within the warranty period will be repaired or replaced at Knoll Systems
option, at no charge. Knoll Systems will not be responsible for the actual cost of
installation or removal of the product, nor for any incidental or consequential
damages. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation may not apply to you. This
warranty gives you specific legal rights. You may have additional legal rights
that vary from state-to-state.
Knoll Systems www.knollsystems.com
145 Tyee Drive Point Roberts, WA 98281
12140 Horseshoe Way, Richmond, BC V7A 4V4
Telephone: (604) 272-4555, Fax (604) 272-5595
Made in Canada
Knoll Systems All Rights Reserved
20-25 feet (6-8 meters)
50 degrees off axis
1000' (300m) or even more with
larger gauge wire
3 conductors, minimum 24-gauge
to 200'; 22-gauge up to 500';
20-gauge to 1000'
Unregulated 12VDC, 40mA
2.65" x 2.9" x 1.1"
(67mm x 74mm x 28mm)
IR100
Tabletop Infrared Receiver
Installation Instructions v1.3
Warning: To be installed and/or used in accordance with
appropriate electrical codes and regulations.
Introduction:
Thank you for your purchase of a Knoll IR100
infrared receiver. This receiver features the ability to pick up a
remote control infrared signal and relay it on wires to another
location up to 1000' (or more).
Features:
Tabletop box design
available in black and light
grey colors.
Will relay almost all remote
control types (except some
B & O models).
Can be connected with
almost any three-conductor
wire including cat 5.
Requires very little power. Suggest using PS1205
12 VDC 500 mA for up to 10 IR100 receivers.
Up to 10 or IR100, IR210, IR220, IR230 and or IR250
can be connected in a single system.
Connects with a three wire connector or RJ45 via cat 5
wire.

Installation Tips

1. Follow all local electrical & building code requirements.
2. The IR100 is usually mounted on a tabletop. For easy
installation and to ensure reliability, it is suggested that a or
PS1205 (500 mA) 12 VDC unregulated power supply, IR31
(single) or IR34 (dual) emitters and one of the following: IR54
(decora inwall style, 4 output) or IR55 (tabletop style, 4
output) connection block, are used.

Advertisement

loading

Summary of Contents for Knoll IR100

  • Page 1: Installation Tips

    5. Systems within the warranty period will be repaired or replaced at Knoll Systems option, at no charge. Knoll Systems will not be responsible for the actual cost of  Requires very little power. Suggest using PS1205 installation or removal of the product, nor for any incidental or consequential 12 VDC 500 mA for up to 10 IR100 receivers.