1. Icemaker

• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 1/4" nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Storage bin and drip tray drain outlets are 3/4" FPT. A minimum of 3/4" nominal ID hard
pipe or equivalent is required for the storage bin and drip tray drain lines.
Storage Bin
Drain Outlet
3/4" FPT
Drip Tray
Drain Outlet
3/4" FPT
Fig. 4
Icemaker
Stand
Vent
Tube
Minimum 3/4" Nominal ID
Hard Pipe
DCM-751BAH(-OS)
Icemaker Water
Icemaker Water Supply
Supply Inlet
Line Shut-Off Valve
1/2" FPT
Minimum 1/4" Nominal ID
Copper Water Tubing
Icemaker Water Supply
Line Drain Valve
18
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the
drain.
2-inch (5-cm)
air gap
Floor Drain