Download Print this page

Transfer Switch Guide - Honda GENERATORS AND WELDERS Parts List

Advertisement

GENERATORS AND WELDERS
GENERATOR MODELS
EU1000i, EU2000i
(Duplex Receptacle
Connection)
EX3300, EM3500X, EZ3500
EZ5000, EG3500, EB3500*
EM3800SX, EB3800X*
L14-20P Plug
EX4500, EX5500, EB5000*
EG5000, EM5000, EU6500is
EM5000iS/EM7000iS
EM6000GP, EB6500*
ES6500, EM6500SX1A
L14-30P Plug
EB5000i, EB7000i
(i-Pro series)
EU3000is, EB3000c
EM3000c, EB3000cKAG
EW171
L5-30P Plug
EB11000, EB12D*
EB11000K1*
CS6365N Plug
* When connecting an EB series generator to a transfer switch, please refer to Generator Service Bulletin #20.
i-Pro series EB5000i & EB7000i generators are NOT transfer switch compatible, and should not be connected to a transfer switch.
A qualified electrician must install transfer switches and power inlet boxes, and the connection must comply with all
applicable laws and electric codes.
Power
Inlet Box

TRANSFER SWITCH GUIDE

POWER CORDS
Connects Generator to
Inlet Box or Transfer
Switch
Use Standard Outdoor
Extension Cord
20A/120V 50 ft. Max
20 amp 125/250V
12 gauge 4-wire
L14-20 ends
06580-124-010AH 10 FT
06580-124-025AH 25 FT
06580-124-050AH 50 FT
30 amp 125/250V
10 gauge 4-wire
L14-30 ends
06580-104-010AH 10 FT
06580-104-025AH 25 FT
06580-104-050AH 50 FT
(Please see page 5-6 for
molded cord sets)
N/A
30 amp 125V
10 gauge 3-wire
L5-30 ends
06582-103-010AH 10 FT
06582-103-025AH 25 FT
06582-103-050AH 50 FT
50 amp 125/250V
6 gauge 4-wire
06580-064-010AH 10 FT
06580-064-025AH 25 FT
30 Amp
50 Amp
POWER INLET
BOXES
For hardwiring to
Transfer Switch
N/A
15 Amp 1 Circuit Indoor Transfer Switch
For generators up to 2000 watts, includes 5-15 male inlet.
Part# 32314-151FT (Surface Mount Only)
20 Amp 125/250V
20 Amp 6 Circuit Indoor Transfer Switch
L14-20
For generators up to 5000 watts, incl L14-20 male inlet.
Part# 32311-189EF (Surface Mount Only)
32314-189-020AH
30 Amp 125/250 V
30 Amp 6 or 10Circuit Indoor Transfer Switch
L14-30
For generators up to 7500 watts. Incl L14-30 male inlet.
Expandable to 16 circuits. Hardwire or use plug-in cord
connection.
32314-189-030AH
Bottom inlet
Part# 32311-189008 (6–Circuit Transfer SW)
Part# 32311-189006 (10–Circuit Transfer SW)
32316-189-PB30
Part# 32314-301060R (10–Cir. Outdoor SW)
-----------------------------------------------------------------------------------------------------------------------------------------------
Front inlet
30 Amp 125/250 Volt kits available (page 5-4)
N/A
30 Amp 125 Volts
30 Amp 125 Volt 6-Circuit Indoor Transfer
L5-30
Switch For generators up to 3750 watts. Incl L5-30 male
inlet. Expandable to 16 circuits. Hardwire or use plug-in
cord connection.
32315-189-030AH
Part# 32311-189018
50 Amp 125/250V
50 Amp 12 Circuit Indoor Transfer Switch
CS6365
For generators up to 12,500 watts. Incl 50A Inlet.
Hardwire or use a plug-in cord connection. Expandable to
32314-189-055AH
16 circuits.
Bottom inlet
32316-189-PB50
Part# 32311-18950A
Front inlet
NOTE: Door is open
for illustration
purposes and MUST
be closed when the
generator is
operating
20 Amp
30 Amp
TRANSFER SWITCHES
UL Listed
Not Transfer Switch compatible

Advertisement

loading