Sharp AQUOS LC-70LE735U Operation Manual page 64

Hide thumbs Also See for AQUOS LC-70LE735U:
Table of Contents

Advertisement

Using a PC
• The TV can be controlled from a PC, control panels
and other devices using the RS-232C or IP.
Use a cross-type RS-232C cable, ETHERNET cable
(commercially available) or wireless LAN for the
connections.
o This operation system should be used by a person who is
accustomed to using computers.
[] Communication
conditions
for IP
Connect to the TV with the following settings made for
IP on the PC.
TOP/IP
Set the IPaddress on the TV menu
None (Do not select Telnetor SSH)
Set a port number on the TV menu
(Controlport)
When you set your ID and password on the TV menu,
you need to enter them as soon as you connect to the
TV.
o The connection will be cut off when there has been no
communication
for 3 minutes.
Example
[] Communication
conditions
for RS=232C
Set the RS-232C communication settings on the PC to
match the TV's communication
conditions.
The TV's communication settings are as follows:
9,600 bps
8 bits
None
1 bit
None
[] Communication
procedure
Send the control commands from the PC via the RS-
232C or IP.
The TV operates according to the received command
and sends a response message to the PC.
Do not send multiple commands at the same time.
Wait until the PC receives the OK response before
sending the next command.
[] Command
format
EightASCII codes ÷ CR
021031041pl
IP2 P3IP4141
", .........................................................
/
/
\ ...........................................................
]...............................................
/
/
Command 4-digits
Parameter4-digits
Return code
Command 4-digits: Command. The text of four characters.
Parameter4-digits: Parameter0-9, x, blank, ?
[] Parameter
Input the parameter values, aligning left, and fill with
blank(s) for the remainder. (Be sure that 4 values are
input for the parameter.)
When the input parameter is not within an adjustable
range, "ERR" returns. (Refer to "Response code format".)
Any numerical value can replace the "x" on the table.
When "?" is input for some
commands, the
present setting
value responds.
1 Press MENU to display the MENU screen, and then
press 4/!_
to select "Initial Setup",
2 Press A/T
to select "lnternet Setup", and then
press ENTER,
3 Press A/T
to select "Network Setup", and then
press ENTER,
4 Press A/T
to select "IP Control Setup", and then
press ENTER,
5 Press _/!_
to select "Change", and then press
ENTER.
6 To use IP Control, press 4/!_
to select "Enable",
and then press ENTER.
7' Set the device name.
8 Set your Iogin ID and password.
9 Set the port to use with IP Control.
10 Confirm the settings, and then press "OK".
[] Response
code
format
Normal response
Problem response (communication
error or incorrect command)
Return
code
(0DH)
Return code (0DH)
Q-
63