Grizzly G0490 Owner's Manual page 39

8" x 76" jointer w/ parallelogram beds
Hide thumbs Also See for G0490:
Table of Contents

Advertisement

Adjusting/Replacing Knives
Before adjusting or replacing the knives, the tables
Must be parallel with each other (refer to check/
Adjusting Table Parallelism on Page 40).
in the adjustment procedure, both tables are low-
ered so that the knife setting gauge will fit on the
cutterhead, as shown in figure 55, and the knife
heights are set to just touch the middle pad of the
gauge.
the knife setting gauge makes it easy to ensure
that the knives project out of the cutterhead evenly.
after using the gauge to set the knives, you have
to re-adjust the outfeed table height to ensure that
it is even with the knives at their highest point of
rotation (refer to Setting Outfeed Table height
on Page 43 for detailed instructions).
figure 55. using the knife setting gauge.
Model g0490/g0490X (Mfg. since 3/09)
the Model g0490 comes with set screw and
knife lifter assemblies inside the cutterhead that
are used to adjust the height of the knives (see
figure 56).
Beveled Edge
Set Screw
& Knife Lifter
Assembly
figure 56. Cutterhead profile diagram.
Tools Needed
Knife setting gauge .......................................... 1
hex Wrench 3mm .............................................. 1
Wrench 10mm ................................................... 1
To adjust/replace the knives:
1.
DisConnECt JointEr FroM poWEr!
2.
remove the cutterhead guard from the table
and move the fence back as far as it will go.
3.
remove the rear stand panel to access to the
motor pulley.
4.
put on heavy leather or Kevlar™ gloves to
protect your hands from the sharp knives.
5.
rotate the motor pulley so that one knife is at
top dead center.
Gib
Gib Bolt
Qty
-37-