Designer collection

Advertisement

Dimensional Diagrams
Ducted
Pre-Planning Your Installation -
upper
5
min
1/8"
chimney
16
max
1/8"
cover
lower
21
1/4"
chimney
cover
canopy
2
3/8"
19
9/32"
x = distance from hood to cooktop
(varies depending on installation)
x
min - 24", suggested max - 30"
also consult cooktop
manufacturer's recommendation
36"
Note: If 24" or 30" High Backsplash is being installed, the distance between the bottom of the hood and the cooktop (distance x in diagram) is equal
to the height of the Backsplash.
Pre-Planning Your Installation -
instructions before you begin installing this rangehood.
Make your ductrun as straight and short as possible. The ductrun should not exceed
35 equivalent feet if ducted with the required minimum of 6" round duct. Count 45º
angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is a
minimum of 24" of straight duct between elbows if more than one is used. Do
not install two elbows together. If you must elbow right away, do it as far away
from the hood's exhaust opening as possible.
WARNING!
Product specifications are subject to change without notification. Consult the installation instructions before you begin installing this rangehood.
Important: Consult the installation instructions before you begin installing this rangehood.
Ducted
min & max ceiling height examples
x = 24"
x = 26"
x = 28"
x = 30"
min
min
min
min
7'
7'
7'
7'
4 3/4"
6 3/4"
8 3/4"
10 3/4"
max
max
max
max
8'
8'
8'
8'
3 3/4"
5 3/4"
7 3/4"
9 3/4"
cabinet base
Important: Consult the installation
Ductless
10" min
16
max
1/8"
For ducted installations, the
chimneys can be adjusted for
ceilings between 7' 4 3/4" and
8' 9 3/4" depending on the
21
1/4"
distance between the bottom
of the hood and the cooktop
(distance x in Ducted
diagram).
2
3/8"
For ductless installations, the
chimneys can be adjusted
for ceilings between 7' 9
5/8" and 8' 9 3/4" depending
on the distance between
the bottom of the hood and
the cooktop (distance x in
Ductless diagram).
For shorter ceilings, have
the chimney cover(s) cut at
a sheet metal shop.
For
higher ceiling installations,
the High Ceiling Chimney
36"
Kit includes a new 40" upper
chimney which would replace
the 16 1/8" upper chimney
that came with the hood.
upper
chimney
cover
ductless
lower
chimney
cover
canopy
19
9/32"
x = distance from hood to cooktop
x = 24"
(varies depending on installation)
min
x
min - 24", suggested max - 30"
also consult cooktop
7'
9 5/8"
manufacturer's recommendation
max
8'
3 3/4"
cabinet base
Ductless Installations*
For installations where ductwork is impos-
sible or highly impractical, a Ductless
Conversion Kit is available. A charcoal
filter, which attaches under the blower
assembly, absorbs smoke and odors. A
ductless diverter assembly directs the air
out to a lower chimney with vent grates cut
into the sides.
* it is highly recommended that
professional style cooking always be
vented to the outside.
Ductless
min & max ceiling height examples
x = 26"
x = 28"
x = 30"
min
min
min
7'
8'
8'
11 5/8"
1 5/8"
3 5/8"
max
max
max
8'
8'
8'
5 3/4"
7 3/4"
9 3/4"
Rev. 07/11

Advertisement

loading

This manual is also suitable for: