6-5 REFRIGERATING
CYCLE
• Troubleshooting
Chart
CAUSE
STATE OF
STATE OF THE
TEMPERATURE
THE SET
EVAPORATOR
OF THE
REMARKS
COMPRESSOR
PARTIAL
Freezer
Low flowing sound of
A little higher
• Refrigerant level is low due
LEAKAGE
compartment and
Refrigerant is heard and
than ambient
to a leak.
Refrigerator don't
frost forms in inlet only
temperature,
• Normal cooling is possible
r-
cool normally,
when injecting of Refrigerant
m
>
the regular amount.
_>
WHOLE
Freezer
Flowing sound of refrigerant
Equal to ambient
• No discharging of Refrigerant,
m
LEAKAGE
compartment and
is not heard and frost isn't
temperature,
• Normal cooling is possible
Refrigerator don't
formed,
when injecting of Refrigerant
cool normally,
the regular amount.
o
PARTIAL
Freeze
Flowing sound of refrigerant
A little higher
• Normal discharging of
CLOG
compartment and
is heard and frost forms
than ambient
refrigerant,
o
Refrigerator don't
in inlet only,
temperature,
• The capillary tube is faulty.
o
m
cool normally.
o
WHOLE
Freezer
Flowing sound of refrigerant
Equal to ambient
• Normal discharging of
CLOG
compartment and
is not heard and frost isn't
temperature,
Refrigerant.
co._
Refrigeratordon't cooL formed,
MOISTURE
Cooling operation
Flowing sound of refrigerant
Lower than
• Cooling operation restarts
CLOG
stops periodically,
is not heard and frost melts,
ambient
when heating the inlet of
temperature
capillary tube.
o
COMP-
Freezer and
Low flowing sound of
A little higher
• Low pressure at high side
O mo RESSlON
Refrigerator
refrigerant is heard and
ambient
of compressor due to low
"_3-n
;:um
don't cool,
frost forms in inlet only.
temperature,
refrigerant level,
mO
60-4
_
NO COMP-
No compressing
Flowing sound of refrigerant
Equal to ambient
• No pressure of high pressure
O m RESSlON
operation,
is not heard and no frost,
temperature,
part in the compressor.
Z
• Leakage Detection
• Observe discharging point of refrigerant which may be in the oil discharging part in the compressor and hole of evaporator.
Check if compressor
runs or not,
YES
Check if frost
forms or not in
Evaporator.
Frost formed normally
Moisture Clog
_r Normal amount
Faulty
Compressor,
Check Compressor
Check if oil
No frost
leaks or not,
or forms
in inlet only
|
Observe the discharged
amount of Refrigerant,
No or much amount
inject refrigerant to compressor
and check cooling operation,
_ Clogged by dust.
Frost formed normally
YES
v
j,,[ Gas leakage,
(Check the leakage point)
- 14-