INSTALLATION INST UCTiONS
FLOW CHECK (DUCT CONDiTiON TEST)
Your dryer features
FlowSense
TM
, an innovative
sensing system that automatically detects blockages
and restrictions in dryer ductwork. Keeping ductwork
clean of lint buildup and free of restrictions allows
clothes to dry faster and reduces energy use.
NOTE: When the dryer is first installed,
this test
should be performed to alert you to any existing
problems
with the exhaust
duct in your home.
However, since the test performed during normal
operation
provides more accurate
information
on
the condition
of the exhaust duct than does the
installation test, the number of bars displayed during
the two tests may not be the same.
To activate the flow check (Duct condition test) :
NOTE: Dryer heating test must be performed before
proceeding.
Then perform the duct condition test
below:
O
Press and hold the
and
DAMP DRY BEEP
TEMR CONTROL buttons at the same time.
While holding these buttons, press POWER
ON/OFR
O
The dryer will show InS in the number display
to indicate that it is in duct condition testing
mode.
O
Press START/PAUSE. The dryer
will run for approximately
2
minutes to test for blockages
or restrictions to air flow in the
ductwork.
If FLOW SENSE indicator light is on,
the dryer ductwork
has a blockage that
needs to be removed immediately.
IMPORTANT: Do NOT interrrupt the test cycle!
Correct Venting
Restricted or Blocked
Airflow
Avoid long runs or runs with multiple elbows
or bends.
Check for blockages and lint buildup.
--3
Make sure the ductwork is not crushed
or restricted.