Available languages

Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical shock.
4=
Attach the 2 green (or green and yellow) ground wires from
the home power supply cable and the exterior-mounted
vent
motor wiring to the green ground screw.
IMPORTANT: Exterior vent motor wires must be connected in
the terminal box as shown.
5. Connect the 2 blue wires together using UL listed wire
connectors.
6. Connect the 2 brown wires together using UL listed wire
connectors.
7. Connect the 2 white wires together using UL listed wire
connectors.
8. Connect the 2 black wires together using UL listed wire
connectors.
9. Tighten conduit connector clamp screws.
10. Replace the terminal box cover and secure with screw.
11. Reconnect power.
1=
2=
Push and hold the button on the top of the downdraft vent for
a few seconds. The retractable section of the downdraft vent
will rise. The blower will start immediately if the blower control
knob is set to an "on" position.
Position the top trim over the retractable section and snap
trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information
on ordering, see the "Assistance or Service"
section.
B
E
A. Top trim
B. ON/OFF button
C. Blower control slider
D. End cap
E. Filters
3. Slide the control slider on the side of the vent to check the
speed of the blower.
If the blower does not operate:
Check that filter or filters are pressed in as far as they
will go.
Check that circuit breaker has not tripped or a household
fuse blown.
Check downdraft
fuse located under power board.
4. Connect vent system to 10" (25.4 cm) round vent collar plate.
Position vent to avoid wall studs and floor joists. Complete all
vent work. Use clamps to seal all joints.
Vertical vent for wall-mounted
installations should pitch down
slightly toward the vent to allow moisture to run outside.
5. Install cooktop according to manufacturer's
instructions.
Check that rear of cooktop overlaps edge of retractable
downdraft vent by 3/8"(9.5 mm). See "Countertop
Cutout
Dimensions"
in the "Location Requirements"
section.
NOTE: To get the most efficient use from your new retractable
downdraft vent, read the "Vent System Use" section.