INSTALLATION
INSTRUCTIONS
EXTERIOR-MOUNTED
VENT MOTOR
KIRD and YKIRD
Models
Only
IMPORTANT:
Exterior blower Model No. KPEU722M [1200 cfm
(34.0 m_/3)] cannot be used with this retractable downdraft vent
system.
NOTE: Exterior-mounted
vent motor installations require exterior
blower system, Model No. KPEC992M [900 cfm (25.5 m3/m)],
available from your dealer or authorized
parts supplier.
Determine which venting method is best for your application.
Vent system can terminate through either the wall or roof.
Island location
,[7
,
Built-in cabinet
locations
A
B
A. Left venting
B. 10" round 90 ° elbow
B
A
A. Right venting
g.
o
10" round 90 elbow
Roof Venting
A. 10" (25.4 cm) round vent
Calculating Vent System Length
It is recommended
that you use round vent instead of rectangular
vent, especially if elbows are required. If rectangular vent is
required, it should be transitioned
to 10" (25.4 cm) round vent as
soon as possible.
Maximum
Length of Vent System
Vent
Length
10" (25.4 cm) round
40 ft (12.2 m)
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
10" (25.4 cm) Round
45 ° elbow
2.5 ft
_
(0.8 m)
0
90 ° elbow
5.0 ft
(1.5 m)
15