Download Print this page

KitchenAid KUCV02FRMT1 Use & Care Manual page 5

Integrated compactor

Advertisement

Electrical
Shock
Hazard
Plug into a grounded
3 prong outlet.
Do not remove
ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure
to follow
these
instructions
can result
in
death,
fire,
or electrical
shock.
Recommended Grounding Method
This compactor
is for use on a single phase, 115-volt, 60 Hz, AC
only 15- or 20-amp fused and properly grounded circuit and is
equipped with a grounding plug as shown below. It is
recommended
that a separate circuit serving only this appliance
be provided.
This compactor
must be grounded while in use to reduce the risk
of electric shock. The compactor
is equipped with a three-
conductor cord and 3 prong grounding-type
plug to fit the proper
grounding-type
receptacle. The green (or green and yellow)
conductor
in the cord is the grounding wire. Do not connect the
green (or green and yellow) wire to a live terminal.
NOTE: Proper installation is your responsibility.
Make sure you
have everything necessary for correct installation. It is the
personal responsibility
and obligation of the customer to contact
a qualified installer to assure that electrical installation meets all
National and Local codes and ordinances.
Tools needed:
Gather the required tools and parts before starting installation.
Level
Phillips No. 2 screwdriver
Tape measure
Flat-blade screwdriver
Pliers
5/16"Hex-head socket wrench
Scissors
Utility knife
IMPORTANT:
Do not grasp control panel to move compactor.
Slide compactor
onto cardboard or hardboard before moving
compactor
across floor to avoid floor covering damage.
Do not allow the rear frame of the compactor to touch the
floor covering when lifting or moving compactor.
Undercounter
Installation
NOTE: Installation hardware is not provided with full cabinet
models.
1. Measure the height of your cabinet opening. The top of the
compactor
should be at least 1/s" (3 mm) from the top of the
cabinet opening.
The rear wheels are preset for a cabinet opening height of
34V4" (87 cm) (Position 1).
To adjust for other cabinet opening heights:
Loosen self-tapping
screw just enough to clear stud from
hole in position "1 ."
Move the rear wheel and stud to position "2" or "3" as
needed for your cabinet opening measurement:
Position 2:341/4 '' to 347A6 '' (87 to 87.5 cm)
Position 3:347A6 '' to 34%" (87.5 to 88 cm)
NOTE: To level the unit in position 3, you may need to
add shims under the leveling legs.
Tighten screw. Repeat for other rear wheel.
D
A. Wheel bracket assembly
C. Locating stud
B. Cabinet
D. Self-tapping
screw (pivot)

Advertisement

loading