Installation Of Vent System, Sidewall - Kenmore ELITE 153.331000 Use & Care Manual

Hybrid gas water heater 25 u.s. gal (94.6 litres)
Hide thumbs Also See for ELITE 153.331000:
Table of Contents

Advertisement

MORTAR OR
I I
II
.,,_,
METAL PLATES
SILICONE IIt.s
II /'/
MESH PROTECTIVE
INSIDE EXHAUST
111,:1P
PVC
II.._-|1,_- BUILDING
COUPLING
U
WALL
EXHAUST
VENT TERMINAL
- ALL MODELS
FIGURE 22
INSTALLATION OF VENT SYSTEM, SIDEWALL
With the route of the venting system and selection
of
materials completed, as discussed in the section of this
manual titled "Planning The Vent System", the through-the-
wall vent terminal in place and the first section of piping,
up to first elbow, installed at the rubber coupling, it is time
to complete the installation of the venting system for the
sidewall installation.
Before completing the installation of the venting system
be sure to read the sections of this manual discussing the
proper method of cutting and cementing PVC pipe and
fittings in the "Vent Pipe Preparation" section.
It is recommended
that the completion
of the venting
system start at the rubber coupling and run to the coupling
on the inside wall of the vent terminal (see Figure 23).
MORTAR
OR
WALL
PLATE
SILICONE
(OPTIONAL)
CAULK
./
PVC VENT
/
TERMINAL
WITH
SCREEN
INSIDE
FROM
WATE
R
HEATER
PVC
COUPLING
f
1 FOOT
IV]IN.
OUTSIDE
OF
BUILDING
WALL
VENT
TERMINATION
FIGURE 23
The vent system piping should be supported every 5 ft.
(1.5m) of vertical run and every 3 ft. (91cm) of horizontal
run. All piping and fittings must be joined by the proper
procedures as described under "Vent Pipe Preparation".
MAXIMUM
EQUIVALENT
FEET.
SEE TABLE
1.
MIN.
12" (30cm)
OR
ABOVE
ANTICIPATED
SNOW
LEVEL
FLOOR
VENT TERMINAL
J
GRADE
FIGURE 24
6 in. (15 cm)
_
/..
MIN. LENGTH
=
_II ::_"_'.[I "
ATTACH
'll
SEALANT
TERMINATION
_
.-.j_f.f.]
i'l'" •" "" ,H. _.
ELBOW
<_U
"_
__
,IF...,.: VENT PIPING TO BE
t
RODENT
P
Pll."..":
: SLOPED
<DOWN_
/
SCREEN/
/H
": '(';:
TOWARvD EHNETA'_vERE
R
12 in.
(INSTALLINTO
/
I{,. "':": "_"" "
FROM COLLECT
NG.
(30 cm) min.
ELBOW)
SEALANT
l:l'. ;: :"
/
GROUNDIt':"::":
LEVEL*\If!:::_
, vi{,,-,..\v.
A,.
• WHERE SNOW COVER IS NORMAL DU RING WINTER, ENSURE SU FFICIENT
VENT CLEARANCE
TO PREVENT
BLOCKAGE
OR ICE BUILDUP.
FIGURE 25
Part Number 320169-001