KitchenAid KIRD802HSS1 Use And Care Manual page 9

30"/36" retractable downdraft vent systems
Hide thumbs Also See for KIRD802HSS1:
Table of Contents

Advertisement

6[]
Turnthe controlknobon
sideof ventto checkthe
operationandspeedof blower.
If blowerdoesnot operate:
• Check that filter or filters are
pressed in asfar as theywill go.
Check that circuitbreakeris not
tripped or housefuse blown.
Disconnect p ower.Check that
wire connections havebeen
madecorrectly.
• Reconnect power.
7= Connect v ent systemto
blower. V entsystemmustendwith
a wall or roof cap.Useduct tapeto
sealalljoints.
18=
Installcooktopaccording
to manufacturer's i nstructions,
Check thatrearof cooktopoverlaps
edgeof retractable downdraftvent
by 3/8"(9.5mm).
To get the most
efficient
use
from
your
new retractable
downdraft
vent,
read the Use
and Care Information
section
on page
12.
Keep Installation
Instructions
and Use and Care
Information
close by for
easy reference.
KIRD and YKIRD
MODELS
ONLY
NOTE: Exterior-mounted
vent
motor installations
require exterior
blower
system, Model No.
KPEC992M [900 cfm (25.5 m3/m)],
available
from your dealer or
authorized
parts supplier.
iMPORTANT: Exterior blower
Model No. KPEU722M [1200 cfm
(34.0 m3/3)] cannot be used with
this retractable
downdraft
vent
system.
island location
Built-in cabinet
location
Built-in cabinet
location
Roof venting
L_______F
'\\
,
10" (25.4 cm)
round
vent
Maximum
length
of vent
system
Vent
Length
10" (25.4 cm) round
40 ft. (12.2 m)
Vent length is given as a general
reference
only. For a longer vent
run, or smaller vent system,
contact a qualified
and trained
vent installer.
Check with local
codes for makeup air
requirements,
if any.
For best performance,
use no more
than three 90 ° elbows.
If more than
one elbow is used, make sure that
there is a minimum
of 24 inches
(61 cm) of straight
vent between
any two elbows.
Do not install two
elbows together.
It is recommended
that you use
round vent instead of rectangular
vent, especially
if elbows are
required.
If rectangular
vent is
required,
it should be transitioned
to 10" (25.4 cm) round vent as
soon as possible.
Determining
the length of system
you need:
To calculate the length of system
you need, add the equivalent
feet
for each duct piece that will be
needed. See example
for 10"
(25.4 cm) round vent system.
10" (25.4 cm} round
vent system
E
Maximum
length = 40 ft. (12.2 m)
2 - 90 elbows
10 ft. (3 m) straight
Length of 10"
(25.4 cm) system
= 10 ft. (3.05 m)
= 10 ft. (3.05 m)
= 20 ft. (6.1 m)
NOTE:The exterior-mounted
vent
motor requires a separate wiring
cable that should
be installed
at
the same time the vent work is
installed.
left vent
right vent
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kird862hss1Gz7936xhs1Gz7930xhs1

Table of Contents