KitchenAid KIRD802HSS1 Use And Care Manual page 8

30"/36" retractable downdraft vent systems
Hide thumbs Also See for KIRD802HSS1:
Table of Contents

Advertisement

bracket for
rear venting
d. Remove screws attaching
brackets to each side of blower.
Reposition
brackets on blower
as shown.Then
reinstall
screws.
e. Reinstall blower
in blower
box
with mouth of blower
pointing
out open side of blower
box.
Secure blower
to blower
box
with 6 Phillips-head
screws.
NOTE: Square metal frame
attached to mouth of blower
must
be installed
for proper operation.
f. Attach metal cover from parts
bag over down-venting
knockout
in blower
box. Remove rear
knockout cover on back of vent
base.
g. Reconnect blower
wiring
cable.
Secure wiring
cable in 2 black
plastic clips inside vent
base.The wiring
cable must be
properly
secured in the 2 clips
(see step b.) Reattach blower
box to downdraft
vent base with
4 hex nuts.
. Attach backdraft damper
over blower
box knockout with 2
Phillips-head
screws.
= Remove the 2 Phillips-head
screws attaching
the wiring
box
cover. Determine
which direction
(rear or down) electrical
connection
will need to run from appliance
wiring
box. Remove rear or bottom
knockout and install conduit
connector.
Excessive
Weight Hazard
Use two or more people to move
and install downdraft vent.
Failure to do so can result in back
or other injury.
[] Insert downdraft
vent
into countertop
cutout.Two
people
are recommended
to support the
weight
of the downdraft
vent
during lifting.
Position downdraft
vent so it is centered
in cutout and
parallel to edge of cutout. Check
that downdraft
vent is level
vertically.Then
fasten lower
support legs to cabinet floor with
screws.
When attaching
undercounter
bracket
to underside
of countertop,
make
sure that the screw length will not go
through
countertop
when tightened.
1 [] Attach one undercounter
bracket on front upper right
corner of downdraft
vent with slot
over vent mounting
hole and
flange against countertop.
Attach
other bracket to left side of
downdraft
vent. Carefully
drill
starter holes through
undercounter
mounting
brackets
into underside
of countertop.
Insert appropriate
length screws
into holes and tighten
brackets to
countertop.
Electrical
Shock Hazard
Disconnect
power before
servicing.
Connect ground wire to green
ground screw in terminal
box.
Failure to do so can result in
death or electrical shock.
12=
Disconnect
power.
green
ground
screw
wiring
box
conduit
connector
I
3=
Remove required
knockout
and install conduit
connector.
Feed the power supply
cable through
the conduit
connector
and into the wiring
box.
Connect the white wires together
with a twist-on
wire connector.
Connect the black wires together
with a twist-on
wire connector.
Attach the green (or green and
yellow)
ground wire to eyelet with
green ground
screw.Tighten
the
conduit
connector
clamp screws.
Replace the wiring
box cover.
14_
Reconnect power.
microswitches
behind filters.
ON/OFF
button
top trim
_filter
or filters
depending
on
model
blower
control
knob
end
cap
5
[] Push and hold for a few
seconds the button on the top of
the downdraft
vent. Retractable
section of downdraft
vent will rise
and blower will start. Position the
top trim over the retractable
section and snap trim into place.