Probe
(cont'd)
Fig. 1
Probe error message:
If the error message "Prob ERR" displays (Fig. 1), check
to be sure that the probe connector is fully inserted into
the receptacle. If the probe is fully inserted in the
receptacle and the error message continues, the probe
may be defective and need replaced.
When "Prob ERR" displays, the oven control will not
permit any oven feature to activate until corrected or the
probe is removed. If the error message continues, remove
the probe from the receptacle and oven.
"Probe Too Hot" message:
When the message "Prob"
... "Too"...
"Hot" ... flashes in
the display, the probe sensor temperature
has exceeded
250°F (121°C). If the probe is not removed this message
may continue until the sensor reaches 300°F (149°C) or
higher, at which time the oven will automatically
turn OFF
and display "Prob ERR" message.
This message may have been generated if the probe
sensor is exposed to direct oven heat or the food
internal temperature
is over 250°F (121°C). Be sure the
probe sensor is fully covered by the food or if the food is
done, press cancel and remove food and probe from the
oven.
handle
Fig. 2
During the cooking process the internal food
temperature
will display by default. To review the
target temperature
press the probekeypad once.
After 6 seconds the display will revert back to the
internal food temperature.
• To assure temperature
accuracy, do not remove the
probe from the food or receptacle until the desired
internal temperature
is met.
• If the probe is active and the probe is removed from
the receptacle only, the probe feature will cancel but
the oven will continue to cook.
• If the probe is active and the probe is removed from
the food only, the probe feature will remain active,
but the displayed internal food temperature
may no
longer be reliable. This may eventually generate a
"Probe Too Hot" message.
• The oven will automatically
turn OFF if the probe
sensor reaches 300°F (149°C) or more.
• The probe feature cannot be set with broil or self-
clean.
To change the target temperature
while cooking,
"_
keypad once. Use the numeric
press the
probe
keypads to change the target temperature.
Press the
start keypad to accept any change.
probe
cable
probe
sensor