Table of Contents

Advertisement

Available languages

Available languages

Quick Links

IGGS & STRATTO
®
rta I
G
rator's
I
This generator is rated in accordance with CSA(Canadian Standards
Association) standard C22.2 No. 100-04 (motors and generators).
8RIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, W ISCONSIN,U.S.A.
Manual No. 206883GS
Revision E

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Briggs & Stratton 206883GS

  • Page 1 IGGS & STRATTO ® rta I rator's This generator is rated in accordance with CSA(Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators). 8RIGGS & STRATTON POWER PRODUCTS GROUP, LLC MILWAUKEE, W ISCONSIN,U.S.A. Manual No. 206883GS Revision E...
  • Page 2 Thankyou for purchasing this quality-built Briggs & Stratton® generator. We are pleased that you've placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service. This manual containssafety information to make you aware of the hazards and risks associated with generators and how to avoid them.
  • Page 3: Table Of Contents

    Table of Contents Operator Safety ......... Equipment Description......... important Safety information ........Assembly ........Unpack Generator ..........Install Wheel Kit..........Verify Engine Oil Level......... Add Fuel............ System Ground ..........Connecting to a Building's Electrical System......Generator Location ........... Featuresand Controls......Cord Sets and Receptacles ........
  • Page 4: Operator Safety

    Operator Safety importantSafety information The manufacturer cannot possibly anticipate every possible EquipmentDescription circumstance that might involve a hazard. The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work Read this manuaJ carefully and become famiJiar ..
  • Page 5 _i_ WARNING Starter cord kickback (rapid retraction) will puii hand and arm toward engine faster than you can let go which could cause broken bones, Using a generator indoors CAN KiLL YOU iN MINUTES, fractures, bruises, or sprains resulting in serious injury.
  • Page 6 ,A. CAUTION Excessively high operating speeds could _i_ WARNING Generator voltage could cause electrical result in minor injury and/or generator damage. ')dhl shock or burn resulting in death or serious Excessively low speeds impose a heavy load. injury. • DO NOTtamper with governor spring, links or other parts to •...
  • Page 7: Assembly

    Install the wheel kit as follows: Assembly 1. Tip generator so that engine end is up. F[-_-_I Read entire operator's manual before you attempt 2. Slide axle (A) through both mounting brackets. to assemble or operate your new generator. 3. Slide a wheel (B) over axle. Your generator requires some assembly and is ready for use NOtiCE Be sure to install wheel with raised hub inboard.
  • Page 8: Verify Engine Oil Level

    Verify Engine Oil Level ,A WARNING Fueland its vapors are extremelyflammable The generator engine is shipped from the factory filled with and explosivewhich could cause burns, oil (API SJ or higher 10W-30). This allows for generator fire or explosion resulting in death, serious injury and/or property damage.
  • Page 9: Systemground

    GeneratorLocation SystemGround The generator has a system ground that connects the Clearances and Air Movement generator frame components to the ground terminals on the _i_ WARNING Exhaustheat/gases could ignite AC output receptacles.The system ground is connected to combustibles, structures or damagefuel tank the AC neutral wire (the neutral is bonded to the generator causing a fire, resulting in death, serious injury frame).
  • Page 10: Featuresand Controls

    Featuresand Controls Read this Operator'sManual and safety rules before operating yourgenerator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. K - Identification Label -- Provides model, revision and A - FuelTank -- Capacity of seven (7) U.S.
  • Page 11: Cordsets And Receptacles

    120 Volt AC, 20 Amp, Duplex Receptacles CordSets and Receptacles The duplex receptacles are protected against overload by a Use only high quality, well-insulated, grounded extension cords with the generator's 120 Volt duplex receptacle. two pole rocker switch circuit breaker. Inspect extension cords before each use.
  • Page 12: Operation

    Operation 5. Grasp recoil handle and pull slowly until slight resistance is felt. Then pull rapidly one time only to start engine. Starting the Engine If engine starts, proceed to step 7. Disconnect all electrical loads from the generator. Use the If engine fails to start, proceed to step 6.
  • Page 13: Connecting Electricalloads

    Connecting ElectricalLoads Stoppingthe Engine 1. Let engine stabilize and warm up for a few minutes 1. Turn OFFand unplug all electrical loads from generator after starting. panel receptacles. NEVERstart or stop engine with electrical devices plugged in and turned ON. 2.
  • Page 14: Don't Overloadgenerator

    Don't OverloadGenerator NEVERadd more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as Capacity described above. You must make sure your generator can supply enough Rated* Additional rated (running) and surge (starting) watts for the items you Toolor Appliance (Running) Surge (Starting)
  • Page 15: Maintenance

    Maintenance Emissions Control Maintenance, replacement, or repair of the emissions controldevices and systemsmay be performed by any MaintenanceSchedule non-roadengine repair establishment or individual. Follow the hourly or calendar intervals, whichever occurs However,to obtain "no charge" emissions control service, first. More frequent service is required when operating in the work must be performed by a factory authorized dealer.
  • Page 16: Enginemaintenance

    Adding Engine Oil EngineMaintenance 1. Make sure generator is on a level surface. _i_WARNING Unintentional sparking could cause fire or 2. Check oil level as described in Checking Oil Level _.dh electric shock resulting in death or serious injury. 3. if needed,slowly pour oil into oil fill opening to the point of overflowing at oil fill.
  • Page 17 Service Air Cleaner Inspect IVlnfflerand Spark Attester Your engine will not run properly and may be damaged if inspect the muffler for cracks, corrosion, or other damage. you run it with a dirty air cleaner. Replacemore often if Remove the spark arrester, if equipped, and inspect for operating under dirty or dusty conditions.
  • Page 18 Clean Cooling S ystem Check Valve Clearance Over t ime debris m ay accumulate in cylinder cooling fins and Regular valve clearance check and adjustment will improve cannot be observed without partial engine disassembly. For performance and extend engine life. This procedure cannot this reason, we recommend you have an authorized service be done without partial engine disassembly and the use of dealer clean the cooling system (A) per recommended...
  • Page 19: Storage

    Change Engine Oil Storage While engine is still warm, drain oil from crankcase. Refill The generator should be started at least once every seven with recommended grade. See Changing Engine Oil. days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use Other Storage Tips: the following guidelines to prepare it for storage.
  • Page 20: Troubleshooting

    Troubleshooting Problem Correction Canse 1. Reset circuit breaker. 1. One of the circuit breakers is open. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no AC 3. Poor connection or defective cord set. 3. Checkand repair. output is avaiiabJe.
  • Page 21: Warranties

    Warranties Briggs& Stratton Emissions Control Warranty Provisions The following are specific provisions relative to your Emissions Control Warranty Coverage.It is in addition to the California, U.S. EPA,and Briggs & Stratton B&S engine warranty for non-regulated engines found in the CorporationEmissionsControlWarranty Operator's Manual.
  • Page 22 The warranty onemissions-related parts isasfollows: LookFor Relevant EmissionsDurability Period and Air Index information On Your Small Off-Road Engine • Any warranted part t hatis notscheduled EmissionsLabel replacement asrequired maintenance intheowner's manual supplied, iswarranted forthewarranty period Engines that are certified to meet the California Air stated a bove.
  • Page 23: Generator Owner Warranty

    Effective November 1,2009; replaces all undated Warranties and all Warranties dated before November 1,2009. LiMiTED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both.
  • Page 24: Specifications

    ® PortableGenerator Product Specifications Starting Wattage ......8,250 watts Wattage* ......5,500 watts AC Load Current: at 120 Volts ......45.8 Amps at 240 Volts ......22.9 Amps Phase ....... Single phase Rated Frequency ......60 Hertz Displacement ...... 18.61 ci (305 cc) Spark Plug Gap ....
  • Page 25 IGGS & STRATTO ® Manualdel 0 Este generador est_ clasificado conforme a ia norma C22.2 No. 100-04 (motores y generadores) de la CSA (Canadian Standards Association [Asociaci6n canadiense de normalizaci6n]). 8RIGGS& STRATTON POWERPRODUCTS GROUP,LLC MILWAUKEE, W ISCONSIN,U.S.A.
  • Page 26 Mnchas gracias per comprar este generador Briggs & Stratton de gran calidad. Nos alegra que haya depositado su confianza en la marca Briggs & Stratton. Siempre que sea utilizado de acuerdo con las instrucciones de este manual, su generador Briggs & Stratton le proporcionar_,muchos aries de buen funcionamiento. Este manual centiene informaci6n sobre seguridad para hacerleconsciente de los riesgos asociados a los generadores y mostrarle c6mo evitarios.
  • Page 27 labia de Contenido Seouridad de operario ......Descripci6n del equipo ........InformaciOn importante de seguridad ......iVlontaje........Desembalajedel generador ........Instale el juego de ruedas ........Comprobar el nivel de aceite del motor ......Agregue combustible .......... Tierra del sistema ..........ConexiOnal sistema el6ctrico de un edificio ......
  • Page 28: Seouridad De Operario

    Seguridad de operatic Sirnboios sobre ia seguridady significados Descripci6ndei equipo Lea atentarnenleeste manual y farniliaricese con Gases T6xicos Contragolpe Descarga El_ctrica el generador. Conozcasus aplicaciones, lirnitacionesy riesgos. Este generador funcJonaen base a un motor de campo el@trico giratorio y de corriente alterna (CA). Fuedise_ado con la finalidad de proveer energia el@trica para I_.mparas Explosi6n Manual d el Operario...
  • Page 29 _i_ ADVERTENCIA El combustible y sus vapores son extremadamente infiamabies y provocar El uso de un generador en un espacio interior PUEDE explosivos, io podria quemaduras, incendios o expiosiones; PROVOCAR LA MUERTE EN POCOS MINUTOS. asi como dafios materiales, lesiones graves o incluso la Los gases de escape del generador contienen muerte.
  • Page 30 _i_ PRECAUCION Las velocidades de funcionamiento _i_ ADVERTENCIA Los gases y el calor de escape podrian inflamar los materiales excesivamentealtas podrian provocar lesiones leves y/o f_,, combustibles y las estructuras o da_ar da_os ai generador. _" el dep0sito de combustible y provocar Lasvelocidades excesivamente bajas incrementan la incendios, asi como da_os materiales, lesiones graves 0 carga de trabajo.
  • Page 31: Ivlontaje

    * ANcates IVlontaje * Gafas de seguridad Su generador requiere de ciertos procedimientos de montaje y Siga estos pasos para instalar el juego de ruedas: solo estar_,iisto para ser utilizado despu6s de haberle suministrado servicio con el combustible y aceite 1.
  • Page 32: Comprobarel Nivel De Aceite Del Motor

    13. Vuelvaa colocar el generador en la posici6n normal de ,A ADVERTENCIA El combustible y sus vapores son funcionamiento (apoyadoen las ruedasy la pata de extremadamenteinflamablesy apoyo). provocar explosivos, io podria /IVfSO Gire el asa en el bastidor del generador s61ocon fines quemaduras,incendios o explosiones;asi de almacenamiento.
  • Page 33: Tierra Del Sistema

    Tierra del sistema Ubicaci6ndel generad0r El generador dispone de una conexi6n a tierra del sistema Espaci0 Libre AJreded0r deJ Generad0r que conecta los componentes dei bastidor a los terminaies de tierra de los enchufes hembra de salida de CA. La tierra ,_, ADVERTENCIA Los gases y ei calor de escape podrian inflamar los materiaies combustibles y del sistema est,.
  • Page 34: Controles Y Caracteristicas

    Controles y caracteristicas Lea este Manual del Operario y reglas de seguridadantes de poner en rnarcha su generador. Compare las ilustraciones con su generador, para familiarizarse con la ubicaci0n de los diversos controles y ajustes. Guardeeste manual para futuras consultas. A =Tanque del Combustible-- El tanque tiene una K - Etiquetade IdentificatiOn -- Proporciona el modelo, capacidad de 7 galones americanos de gasolina sin...
  • Page 35: Juegos De Cordones Y Enchufes Conectores

    Juegosde cordones y enchulesconeclores AV/SO Las tomas el6ctricas pueden marcar un valor nominal mayor que la capacidad de salida del generador. Utilice exclusivamente cables prolongadores de alta calidad, * NUNCAintente conectar un dispositivo que requieram_s amperaje bien aislados y con conexi6n a tierra para la toma done de del que el generadoro ia toma el_ctrica puedensuministrar.
  • Page 36: Operando

    Operando Mueva la paianca de choque hasta ia posici6n "Half" (media) y accione dos veces la manija de retroceso. • Si el motor no arranca, repita los pasos desde Enciendael motor 5 hasta 7. Desconectetodas las cargas el6ctricasdel generador. Use las 7.
  • Page 37: Conexionde Cargas El6Ctricas

    Parada del motor Conexi6n de cargasel6ctricas 1. Deje que el motor se estabilice y se caliente por dos 1. Desconectetodas las cargas el6ctricas de los minutos despu6s del arranque. tomacorrientes del panel del generador. Nunca de arranque o detenga el motor con todos los dispositivos 2.
  • Page 38 6. Repita los pasos 4 y 5 para cada carga adicional que No sobrecaroarel oenerador usted tenga. Capacidad NUNCAa_ada cargas que sobrepasen la capacidad del Debe asegurarse de que su generador puede proveer los generador. Tenga especial cuidado en contar con las cargas suficientes vatios de potencia continua (vatiaje nominal) y adicionales en la capacidad del generador, como se describe vatios de saiida para los eiementos que deseealimentar al...
  • Page 39: Ivlantenimiento

    IVlantenirniento Control de ernisiones Cuaiquier estabiecimiento o individuoespeciaJizado en Ja reparaci6nde rnotoresque no scan de antomoci6n puede Plan de mantenimiento encargarse del rnantenirniento,la sustituci6ny la Siga los intervalos de horas o de calendario, los que sucedan reparaci6nde los dispositivos y sistemas de controlde antes.
  • Page 40: Mantenimiento Del Motor

    iVlantenimiento del motor Comprobaci6n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada _i_ADVERTENCiA Las chispas involuntarias podrian 8 horas de funcionamiento, como minimo. Rellenesi es '_dh provocar incendios o electrocuci6n que necesario. pueden provocar lesiones graves o la muerte.
  • Page 41 Limpie la zona de alrededor del tapOnde vaciado de Servicio del bujia aceite (A), situado en la base del motor, al otro lado del Cambie la bujia ayudar_,a su motor a arrancar m_.s carburador. f_.cilmentey funcionar mejor. 1. Limpie la zona de airededor de la bujia. 2.
  • Page 42 Lirnpie e inspeccioneel apagachispasde la siguienle Cornprobaci6n de holgurade la v_lvula rnanera: Si comprueba y ajusta la holgura de ia v_.ivulareguiarmente, 1. Para retirar la protecci6n del silenciador (A) de el funcionamiento del motor mejorar_,y tendr_ una mayor siienciador (B), retire ios cuatro tornillos que conectan vida _til.
  • Page 43: Almacenamiento

    Almacenamiento Si no se ha a_adido un estabilizador de combustible a la gasoiina, deber_,vaciar completamente el motor utiiizando El oenerador deber_ ser encendido al menos una vez cada un contenedor homoiogado. Dejefuncionar ei motor hasta siete dias y deber_,dejarlo funcionar al menos durante que se agote el combustible.
  • Page 44: Resoluci6N De Problemas

    Resoluci6n de problemas Problemo Causa Action 1. El interruptor autom_tico de 1. Reposicioneel interruptor. circuito est,. abierto. 2. Conexi6n mal o defectuosa del El motor est_ funcionando 2. Revisey repare. juego de cables. pero no existe salida de AC disponsible. 3.
  • Page 45: Garantias

    Garantias DisposicJones de la oarantia contradefectos del sistema de control de ernisionesde Briggs& Stratton A continuaci6n se detallan las disposiciones concretas Garantia de controlde emisionesde California, relativasa la Cobertura de la garantia contra defectos del U.S. EPAy Brigos& $trattonCorporation sJstemade control de emisiones. Se a_aden a la garantia de motores de B&S para motores no regulados, que figura en el Derechosy obligaciones de la garantia Manual del Operario.
  • Page 46 Lagarantia deloscomponentes relacionados conlas B&S. B&S no ser_.responsable de la cobertura de la emisiones eslasiguiente: garantia de fallos de componentes relacionados con el sistema de emisiones cubiertos por ia garantia • Los failos de todo componente cubierto por ia garantia provocados por ei uso de componentes que no se deba sustituir como parte dei plan de complementarios o modificados.
  • Page 47: Garanfia Para El Propietario De Una Generador

    Fechade entrada en vigor: 1 de noviembre de 2009; sustituye a todas las garantias sin fecha y a las de fecha anterior al 1 de noviembre de 2009. GARANT[A LIMITADA Briggs & Stratton Power Products Group, LLC reparar_ o sustituir_ sin cargo alguno cualquier componente del generador port_til que presente defectos de materiales y/o mano de obra.
  • Page 48: Especificaciones

    hera or port til Especificaciones d ei producto Vataje que Empieza ....8,250 Vatios (8,25 kW) Vataje* ......5,500 vatios (5,5 kW) Carga Corriente de C.A. a 120 Voltios ......45.8 Amperios a 240 Voltios ......22.9 Amperios Frecuencia Nominal ..... 60Hz a 3600 rpm Fase ........

Table of Contents