VENTING
[_
Z_
WARNING:
Do not reduce the vent pipe size and
do not common
vent with any other vented appliance
or
stove.
This appliance
must be vented
horizontally
to the outside
with a sealed 4" single wall vent pipe. The appliance's
flue
gasses are under positive pressure and must travel through
a single wall 4" pipe that is sealed gas tight. The 4" single
wall vent pipe can be either stainless
steel (AL29-4C)
or
galvanized steel with at least 26 gauge. B BTNA recommends
the use of stainless steel vent pipe (which is equipped
with
sealing gaskets)
for ease of installation and durability. When
using galvanized
vent pipe a minimum
of 4 sheet
metal
screws per connection
must be installed and all seams must
be sealed
with
an approved
high temperature
silicone
sealant. The vent system must be gas tight. See Fig. 4 for
suggested
venting installation
diagrams.
The 125FX
shall not be vented
in combination
with any
other
appliance.
This appliance
may only
be vented
horizontally
with a dedicated
sealed
single wall vent. The
125FX shall not be vented into masonry chimneys or existing
vertical vents of any material.
CAUTION:
125FX vent system must be installed by a qualified
agency in accordance
with these instructions.
If improperly
installed a hazardous condition
such as explosion or Carbon
Monoxide
poisoning
could
result. BBT North America
will
not be responsible
for improperly
installed appliances.
Establish
vent
clearances
that
comply
with
vent
manufacturer's
specifications.
In all cases follow local codes.
See table below.
The vent diameter
must be 4". The appliance
should
be
located as close to the point of termination
as possible
(see
Fig. 5 for locating
the terminator).
The vent system
should
be as straight and short as possible.
The vent pipe must be
4" single wall stainless steel (AL29-4C)
or galvanized
steel
pipe of 26 minimum
gauge.
Maximum
vent length
is 15
feet (4.6 m) with two 90-degree
elbows.
Subtract
5 feet
from the total vent length for each additional
90-degree
elbow used. No more than four 90-degree
elbows
may be
used. Any short vertical
portion
of vent pipe used in the
vent system
shall be considered
part of the allowable
15
feet (4.6 m) maximum run. Support
the vent run at 4 foot
intervals with overhead
hangers.
Horizontal sections
of vent
must rise 1/4" for every foot of horizontal
length. Any vent
section greater than 45 degrees
is considered
an elbow.
Note:
Single wall pipe should
not be used in concealed,
unoccupied
or unheated locations.
Listed thimbles or collars
are necessary
to pass through
wall partitions.
If the vent
system passes through
combustible
areas where the vent
clearance
requirements
cannot
be maintained,
it is
permissible
to chase straight sections of sealed 4 inch single
wall vent through
5 inch (or greater)
Type-B
vent. The
distance
to combustibles
using this chase technique
is 1
inch. Note: Type-B vent should never be used as the actual
vent system for the 125FX, as it is not gas tight.
Freeze Warning:
As mentioned
on Page 5, negative
air pressure
in cold
climates will cause a reverse airflow in the vent system that
can freeze and damage the Aquastar
heat exchanger
when
not in use. To prevent
this the FXHOOD
horizontal
vent
terminator,
which
was supplied
separately
with the water
heater, needs to be installed
on the end of the horizontal
vent run (see page 8). The FXHOOD
is a CSA approved
vent terminator
for the Aquastar
125FX and has a built in
back draft flapper.
Flue Gas Sensor:
The 125FX is equipped
with a Flue Gas Sensor; it's mounted
on the left side of the draft diverter (Flue Gas Sensor - #33
on page 20). Before leaving the installation
site verify proper
Flue
Gas
Sensor
operation
by temporarily
blocking
termination
outlet. Once
blocked
then operate
the heater,
the unit should shut down within 1-3 minutes when the flue
gases are blocked.
You must reset the electrical
power to
the heater
after
this
safety
test
has been
conducted,
otherwise
the unit will not operate.
The flue gas exhaust temperature
on the 125 FX is 356°F (180°C)
Venting Material
Exhaust vent
Options
Single wall stainless
steel (AL29-4C)
sealed vent pipe
Single wall galvanized
vent pipe (min. 26
gauge and sealed
with high temperature
silicone)
Exhaust vent maximum
Vent pipe within an
diameter
4 inch
4 inch
distance
15 feet (4.6 m) with two
elbows. Less 5 feet for
each additional elbow.
15 feet (4.6 m) with two
elbows.
Less 5 feet for
each additional
elbow.
Clearances
from
venting
material
unenclosed space
See manufacturer s
specifications
3 inches
Vent pipe within an
enclosed space
*See manufacturer's
specifications
NOT PERMISSIBLE
*Stainless steel (AL29-4C) vent pipe manufacturer's are Z-Flex, Protech and Heat Fab. The manufacturer's specified clearances
are identified on the venting material. NOTE: clearance distances are variable depending
if the vent pipe is installed in an
enclosed or unenclosed space, the exhaust flue gas temperature and the orientation of the vent pipe.
6 720 606 601
7