WATER CON N ECTIONS
Install the heater centrally
in the building
if possible
and
make hot water piping runs as short as possible When facing
the heater, the cold water inlet will be on the right and the
hot water outlet on the left..
Although water piping throughout
your structure may be other
than copper, we recommend
that copper
piping be used for
at least three feet before and after the heater (follow local
codes if more stringent).
Plastics or other PEX type plumbing
line materials are not suitable for connecting
directly
to the
water
heater.
Keep water
inlet pipe to no less than 1/2"
(19.05mm)
diameter
to allow the full flow capacity.
If the
cold and hot connections
to the heater are reversed,
the
heater will not function.
The 125FX is provided with one flexible type connector
that
must be connected
to the cold inlet fitting of the water valve
as shown in Fig. 7. The union end of the flexible connector
should be attached
to the rear inlet port of the water valve
with the supplied
washer gasket.
No pipe dope or thread
tape is to be used at this joint.
The 1/2" flexible hot water
outlet line is supplied
attached
to the heater.
Be certain there are no loose particles or dirt in the piping.
Blow out or flush the lines before connecting
to the water
heater. Full port valves should be installed on both the cold
water supply and hot water outlet lines to facilitate
servicing
the heater (see Fig. 7).
For installation
on a private well
system with the use of a pressure tank, the lowest pressure
range setting
recommended
is 30-50
psi (2.07-3.45
bar).
INLET
FLEX
CONNECTOR
WASHER
WATER
FILTER
R VALVE
800-02,1 JS
Connecting the pressure relief valve (PRV)
The listed pressure relief valve supplied with the heater must
be installed
at the time of installation.
Should a discharge
line be added to the PRV no valve is to be placed between
the PRV and the heater.
No reducing
coupling
or other
restriction
may be installed
in the discharge
line. The
discharge
line must be installed such that it allows complete
drainage
of both the PRV and the line. The location
of the
PRV must be readily accessible
for servicing
or replacement
and be mounted as close to the water heater as possible.
To
install the PRV, a suitable fitting connected
to an extension
on a "T" fitting can be sweated
to the hot water line. See
Fig 8.
LJ
©
1
PIPE PRV TO
APPROPRIATE
DISCHARGE
HOT
COLD
6 _2060660!-14.1A]
Fig. 8 - Plumbing and Pressure Relief Valve