WARNING:
CONNECTOR
BLOCK
IS APPROVED
FOR COPPER
WIRE CONNECTION
ONLY.
2. Aluminum Wiring
A. Connect length of copper building wire to range ter-
minal block,
B. Splice
copper
wires
to aluminum
wiring
using
special
connectors
designed
and UoL. approved
for
joining copper to aluminum,
and follow the connector
manufacturer's
recommended
procedure
closely.
NOTE: Wire used, location and enclosure
of splices,
etc., must conform
to good wiring
practice
and local
codes.
5
Speciaa Grounding instructions
WARNING:
1. If local
codes
do not permit
grounding
through
neutral,
disconnect
the strap, located
at
the bottom
of connector
block,
from the frame and cut off to pre-
vent contact with the range body.
To ground
range
frame,
a 4th
grounding
lead
must
be con-
nected to range frame in accord-
ance with local codes, using only
ground
lug and screw°
_,UG
2. Mobile Home Installation--If
this range is provided
with a 3-conductor
cord or cable assembly,
or if local
codes do not permit grounding
through the neutral, the
grounding
strap must be removed and the 3-conductor
cord
or cable
assembly
must
be replaced
by a
4-conductor
cord as follows:
A. Remove the 3-conductor
cord by removing the strain
relief and terminal
lugs from the connector
block.
B. Attach the 4-conductor
cord as described
in STEP
5.1, except attach 4th wire to previous
location
of the
grounding
strap.
6
Anti-Tip Bracket
Hnstallation
An ANTI-TIP
bracket
is
supplied
with
instruc-
tions for installation
in a
variety of locations.
The
instructions
include
a
template,
a parts list and
. F_ _ . .....
-_j:_'.t..
Bracket Installation Tempiate
a list of tools necessary
to complete
the installation.
Read the IMPORTANT
SAFETY INSTRUCTIONS
and
the instructions
that fit your situation before beginning
installation.
WARNmNG
° RANGE MUST BE SECURED BY ANTI-TIP
BRACKET SUPPLIED.
o SEE INSTRUCTIONS
TO INSTALL.
° UNLESS PROPERLY INSTALLED, RANGE
COULD BE TIPPED BY STEPPING OR SIT-
TING ON DOOR. INJURY MIGHT RESULT
FROM SPILLED HOT LIQUIDS OR FROM
RANGE ITSELF.
Attachment
to wail
Bracket
Screw must enter wood or metal
Wail prate
t
Leveling the Range
The range must be leveled_ Leveling
feet are located
on each corner of the base of the range. Remove the
storage drawer and rotate the leveling feet in or out as
require&
To remove drawer, pull it out all the way, tilt
up the front and remove it. To replace, insert glides at
back of drawer beyond stop on range glide& Lift drawer
if necessary
to insert easily.
One of the rear leveling feet will engage the ANTI-TIP
bracket (allow for some side to side adjustment)° Allow
a minimum
clearance
of 1/8" between the range and
the leveling foot that is to be installed into the ANTI-TIP
brackeL
Fina! Check
Be sure all switches are in the "off" position before leav-
ing the range_