Product Data Sheets - Jenn-Air JFI2089AES2 User Instructions

Table of Contents

Advertisement

Available languages

Available languages

PRODUCTDATA SHEETS
Interior Water Filtration System
Model UFK8001AXX-750
Capacity
750 Gallons
(2839 Liters)
I System
tested and certified
by NSF International
against
NSF/ANSI
(_
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against NSF/ANSl
Standard
53 for the reduction
of Lead,
Mercury, Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts, Turbidity,
Asbestos
and Lindane.
This system
has been tested
according
to NSF/ANSl
Standards
42 and 53 for the reduction
of the substances
listed
below.
The
concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
1.88 mg/L
2.0 mg/L _+10%
0.06 mg/L
**
0.05 mg/L
96.84
>97.26
Particulate Class I*
85% reduction
5,700,000 #/mL
Atpar_icles/mLleast
10,000
69,000 #/mL
30,583 #/mL
98.94
99.52
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: (-® pH 6.5
0.010 mg/L
0.153 mg/L _
0.15 mg/L _+10%
< 0.001mg/L
< 0.001mg/L
>99.29%
>99.35%
Lead: @ pH 8.5
0.010 mg/L
0.150 mg/L t
0.15 mg/L _+10%
< 0.001mg/L
< 0.001mg/L
>99.29%
>99.33%
Mercury: @ pH 6.5
0.002 mg/L
0.006 mg/L
0.006 mg/L _+10%
0.0005 mg/L
0.0003 mg/L
90.91
95.70
Mercury: @ pH 8.5
0.002 mg/L
0.006 mg/L
0.006 mg/L _+10%
0.0015 mg/L
0.0008 mg/L
75.93
86.22
Benzene
0.005 mg/L
0.014 mg/L
0.015 mg/L _+10%
0.0011 mg/L
0.0006 mg/L
92.14%
95.71%
p-Dichlorobenzene
0.075 mg/L
0.208 mg/L
0.225 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L 99.74%
99.76%
Carbofuran
0.04 mg/L
0.081 mg/L
0.08 mg/L _+10%
< 0.001mg/L
< 0.001mg/L
98.46%
98.74%
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 _+10%
< 0.001mg/L
< 0.001mg/L
91.67%
92.97%
Atrazine
0.003 mg/L
0.009mg/L
0.009 mg/L _+10%
< 0.002 mg/L
< 0.002 mg/L
75.31%
76.99%
Asbestos
99%
155 MF/L
107to 108fibers/L tt
< 1 MF/L
< 1 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
166,500 #/L
50,000/L min.
< 1 #/L _
< 1 #/L _
>99.99
>99.99
Turbidity
0.5 NTU
10.7 NTU
11 _+1 NTU
0.49 NTU
0.31 NTU
95.2
97.09
Lindane
0.0002 mg/L
0.002 mg/L
0.002 _+10%
< 0.0001mg/L
0.000 mg/L
96.50%
98.72%
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure
71.6°F (20°C to 22°C).
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the yellow (Order)
light comes on. When 100% of the filter's rated life is used,
the red (Replace) light comes on, and it is recommended
that
you replace the filter. For models without filter status lights,
replace the filter every 6 months. Use replacement filter
model UFK8001AXX-750.
2007 suggested retail price of
$49.99 U.S.A./S65.95 Canada. Prices are subject to change
without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected
waters that may contain filterable cysts.
= 60 psig (413.7 kPa). Temp. = 68°F to
Refer to the "Water
Filtration
System"
section
for the
Manufacturer's
name
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
35 - 120 psi (241 - 827 kPa)
Water Temperature
33 ° - 100°F (1 ° - 38°C)
Service
Flow Rate
0.78 gpm
(2.9 L/min.)
@ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents