ICP CHP042AKA1 Installation Instructions Manual
ICP CHP042AKA1 Installation Instructions Manual

ICP CHP042AKA1 Installation Instructions Manual

Split system premium line ac & hp condensers

Advertisement

Installation
Instructions
SPLIT SYSTEM
Premium Line
AC & HP CONDENSERS
Save This Manual for Future Reference
421 01 3201 07
Dec. 2004

Advertisement

Table of Contents
loading

Summary of Contents for ICP CHP042AKA1

  • Page 1 Installation Instructions SPLIT SYSTEM Premium Line AC & HP CONDENSERS Save This Manual for Future Reference 421 01 3201 07 Dec. 2004...
  • Page 2 Installation Instructions Split System Condensers Installation/Startup Information These instructions must be read and understood completely before attempting installation. CAUTION Installation repairs made unqualified Improper installation, adjustment, alteration, service or persons can result in hazards to you and others. maintenance can void the warranty. Installation MUST conform with local building codes or, in the absence of local codes, with the...
  • Page 3: Locating The Outdoor Unit

    I Split System Condensers Installation Instructions Locating The Outdoor Unit: Check local codes covering zoning, noise, platforms. Roof top installations are acceptable providing the roof will support the unit and provisions are made for water drain- If practical, avoid locating next to fresh air intakes, vent or age and the noise or vibration through the structure.
  • Page 4 Split System Condensers Installation Instructions Figure 2 Clearances Recommended Clearances Minimum Clearances 24" 24" 24" 24" 24" 24" Minimum Clearances Minimum Clearances 18" 18" 24" 18" Minimum Clearances 24" 24" 24" 24" 24"...
  • Page 5 MANUAL #42106111400 WITH you are ready to actually make connections to the PRIOR APPROVAL FROM ICP TECHNICAL SERVICE evaporator and to the condenser section. DEPARTMENT. Do not remove rubber plugs or copper caps from the tube ends until ready to make connections at evapora- tor and condenser.
  • Page 6 Split System Condensers _ Installation Instructions Do not let refrigerant lines come in direct contact with Brazing Connections foundation. When running refrigerant lines through the foundation or wall, the openings should be made large Fire Hazard enough to allow for a sound absorbing material to be placed or installed between the tubing and the foundation.
  • Page 7: Electrical Wiring

    I Split System Condensers Installation Instructions The service valve cap is a primary seal for the valve and Recommended Method Of Evacuating must be properly tightened to prevent leaks. Make sure cap System is clean and apply refrigerant oil to threads and sealing sur- 1.
  • Page 8: Control Box Access

    _ Installation Instructions Split System Condensers See Figures 5 thru 8 and Wiring Diagram on unit. Figure 7 |'" " A/C Condenser Typical Low Use of Rigid Metal Conduit Voltage Connections It is recommended that wires be tied together or twisted to- gether inside the conduit.
  • Page 9 I Split System Condensers Installation Instructions I Figure Heat Pump Typical Low Voltage Control Connections ELECTRIC HEAT Indoor Outdoor NO OUTDOOR THERMOSTAT Thermostat Unit -0-- O -- (Heat/Cool Relay) --© -0-- (Compressor) -O-- (Electric Heat) White Rogers 1F92 only, field jumper required Y1 -Wl.
  • Page 10 _ Installation Instructions Split System Condensers 2. Measure and record the suction line refrigeration pres- If the actual superheat readings are lower than shown, the sure. (Measure at the suction line service valve gauge system is most likely over-charged, and charge should be port.) Using Temperature / Pressure Chart convert this removed.
  • Page 11 I Split System Condensers Installation Instructions In some areas, with high humidity, the time interval or tem- To Check System Refrigerant Charge perature termination may require adjustment for complete (Heating Mode) removal of ice from the coil. For best economy, always set The recommended method of addition or removal of to the longest interval or lowest temperature that will keep...
  • Page 12: Maintenance

    _ Installation Instructions Split System Condensers Never use a weather cover over the outdoor unit un- Temperature Adjustment less it is a ventilated type or made of breathable fabric (Demand Defrost) that will allow moisture to evaporate rapidly. A cover that holds moisture in the unit will cause more rust Turn off all power to the Heat Pump.
  • Page 13 I Split System Condensers Installation Instructions SHIPPING BRACKET A shipping bracket has been added to some chassis to increase the stacking height for im- proved warehousing. If present the bracket may be left in place or removed by the installer. NOTE: The bracket is installed using the same screw(s) that secure the service valve.