Troubleshooting - Hoover WindTunnel T Series Owner's Manual

Hide thumbs Also See for WindTunnel T Series:
Table of Contents

Advertisement

Available languages

Available languages

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the
checklist below.
Any other servicing should be done by an authorized service representative.
A WARNING A
To reduce risk of personal injury - unplug vacuum before servicing.
PROBLEM
POSSIBLECAUSE
POSSIBLE SOLUTION
vacuum
won't
run
System
Check
Indicator
has
turned
red
or
Vacuum
won't
pick up
or
Low suction
Dust escaping
from
vacuum
Powered
Hand
Tool brushrell
won't
turn
2. Blown fuse or tripped breaker.
1. Rinsable Filter and/or HEPA
Filter is dirty.
3. Broken or worn Belt.
5. Carpet height setting is
incorrect.
2. Dirt Cup not installed
correctly.
4. Rinsable
and/or HEPA Filter
not installed completely.
2. Blockage.
2. Check fuse or breaker in home. Replace
fuse/reset breaker in home.
1. Clean Rinsable Filter and/or HEPA Filter -
Pg.9
3. Replace
Belt - Pg.12.
5. Set Carpet Height Adjustment
to appropriate
setting for carpet being cleaned
- Pg.7.
2. Review
Dirt Cup removal
& replacement
-
Pg. 8.
4. Review
Filter Removal
and Cleaning.
2. Remove
blockage
- Pg. 11
Smoky/burning
1. Belt broken or stretched.
1. Replace brushroll belt - Pg. 12.
smell detected