Hoover Convrtible U4109 Owner's Manual page 18

Table of Contents

Advertisement

How to replacethe brushes
Disconnect
the deaner
from electrical
outlet.
1. To replace worn brushes,
remove bottom plate, belt and agitator, following
directions given on preceding pages.
iND PLATES
2. Turn end plates of agitator
counterclockwise
until one end
plate comes off.
3. Then pry out end section as
shown.
4. Remove opposite
end plate and
shaft by pulling straight out. Pry
out remaining end section.
5. Remove
brushes
by pulling them
from agitator.
Use pliers if necessary
Slide new brushes
into channels.
Push them in as far as possible.
END SECTION
WASH E R
BEARING
LOCATOR
6. To reassemble, reverse procedure.
Replace first,
the last end section
removed, then end plate and shaft.
Replace remaining end section and
end plate. Be sure end sections are
assembled
with Iocator lined up
with slot in agitator.
7. Should
you accidentally
displace
the bearing
during
disassembly,
reassemble
as shown.
17

Hide quick links:

Advertisement

Table of Contents
loading