Manua!
8peratiun
Starting
1. Turn the engine switch to the ON position. The engine switch enables and
disables the ignition system.
OFF: To stop the engine. RUN: To run the engine.
2. The fuel vaive is iocated between the fuel tank and the carburetor.
When the vaive iever is in the ON position, fuel is aiiowed to flow from
the fuel tank to the carburetor. Be sure to return the fuel vaive iever to
the OFF position after stopping the engine.
3. To start a coid engine, move the choke iever to the CLOSED position.
To restart a warm engine, ieave the choke iever in the OPEN position.
The choke iever opens and cioses the choke vaive in the carburetor.
The CLOSED position enriches the fuel mixture from starting a coid engine.
The OPEN position provides the correct fuel mixture for operation after
starting, and for restarting a warm engine.
4. Operate the Recoil Starter: Turn the key to the "Run" position. Puil the
starter grip iightiy until you feel resistance, then puil briskiy. Return the
starter grip gentiy. Puiiing the starter grip operates the recoil starter to
crank the engine.
ELECTRIC START. For Eiectric Start just turn the key to start.
NOTE: Make sure correct battery is instaiied.
(see battery instaiiation for detaiis)
5. if the choke iever has been moved to the CLOSED
position to start the engine, graduaiiy move it to the
OPEN position as the engine warms up.
Stopping Engine
Turn the engine switch to the OFF position.
2. Turn the fuel vaive iever to the OFF position.
When the engine is not in use, ieave the fuel vaive iever in the OFF position
to prevent carburetor fiooding and to reduce the possibiiity
of fuel ieakage.