GENTRON G2000D Owner's Manual page 13

2000w digital generator
Table of Contents

Advertisement

• Visually
inspect the spark plug. Discard it if the insulator
is cracked
Clean the spark plug with a wire brush if it can be reused.
• Measure
the plug gap with a feeler gauge.
The gap should
be 0.6-0.7mm,correct
as necessary
by carefully
bending the
side electrode.
• Install the spark plug carefully,
by hand, to avoid cross-threading.
Make sure to drain the fuel completely.
During transporting
or during storage.
• After a new spark plug has been seated by hand, it should
be tightened
1/2 turn
with a wrench
to compress
its washer.
If a used plug is being reinstalled,
it should only require
1/8 to 1/4 turn after being
seated.
• reinstall the spark plug cap.
• Reinstall
the spark plug mainenance
cover.
CAUTION:
• The spark plug must be securely tightened. An improperly tightened plug can
become very hot and possibly damage the generator.
• Never use spark plug with an improper heat range.
To prevent fuel spillage when transporting
or during temporary
storage,
the gene-
rator should
be secured
upright in its normal operating
position,
with the engine
switch OFF. The fuel cap level turned fully to the "OFF" position.
Avoid direct sunlight when putting the generator
on a vehicle.
If the generator
is left in an enclosed
vehicle for many hours, high temperature
in-
side the vehicle could cause possible explosion.
Before storing the unit for an extended
period:
Be sure the storage
area is free of excessive
humidity
and dust.
Long-term
storage
(over 30 days) information:
If you need store this engine for a long term (over 30 days), please follow the
following
instructions.
1. Make sure the gas tank is empty.
2. Empty out engine oil.
3. Turn all the the switches
OFF.