Download Print this page

GE GSC22KGRCBB Owner's Manual And Installation page 40

Profile side by side models 23, 25, 26, 27 and 29

Advertisement

Available languages

Available languages

Performance Data Sheet
SmartWaterFiltrationSystem
GWF/ HWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42FJ3.*
(100% safety factors built in for unmotered usage)
Parameter
Chlorine
T&O
Par ticulau-**
USEPA
MCL
Standard
No.
42: Aesthetic
Effects
Influent
Effluent
Challenge
Concentration
Average
Maxlrnmn
2.0 mg/L
+ 10%
0.02 ppm
0.05 ppm
at least 10,000
pm-ticles/ml_
3,978
7,800
% Reduction
Average
Minimum
98.90%
97.37%
98.00%
96.10%
MhL Required
Reduction
> 50%
>85%
S "tmldard
No. 53: Health
Effects
Parameter
Infhmnt
Effluent
Challenge
Concentration
Average
Maximum
Average
Turbidity
11 + 1 NTU***
0.07 NTU
0.i NTU
99.71%
_us
Minimum
50,000
L
26
55
99.97%
lx, ad at pH 6.5
0.15
mg/L
+ 10%
1 ppb
1 ppb
99.37%
lx, ad at pH 8.5
0.15
mg/L
+ 10%
1.8 ppb
4.3 ppb
98.8%
IJndmm
0.002
mg/L
+ 10%
0.00005
ppm
0.00005
ppm
91.93%
Awazine
0.009
mg/L
+ 10%
0.602
ppm
0.003
ppm
76.19%
2,4-1)
0.210
mg/L
+ 10%
0.042
ppm
0.096
ppm
8&89%
As_stos
107 m l& fibers/L;
0.32
MFL/ml
1.2 MFL/ml
99.95%
fibers
greatcr
than
10 micrometers
in length
USEPA
MCL
1 NTU***
99.95%
Rvduction
15 ppb
15 ppb
0.0002
ppm
0.003 ppm
0.100 ppm
99%
% Reduction
Miniramn
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
* Testedusing a flow rate of 0.5gpm; pressureof 60psig, pH of Z5 ± 05; temp. of20°:_ Z5°C
*_ Measurement i n Patticles/ml Particlesusedwer_05-1 microns
*** NTU=Nephelemetfic T urbidity units
MhL Reqlfired
Reduction
0.5 NTU
> 99.95%
0.010
lng/E
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.07 mg/L
99%
Operating Specifications
• Capacily:
certified
for up t( 300 gall( ns (l 135 1); up to six months
for models
wilhout
a replacement
filter indicator
light; up
to one year for models
with a replacement
filter indicator
light
• Pressure
requirement:
40-120
psi (2.8-8.2
bar),
non-shock
• TeInperamre:
33-100°F
(0.6-58°C)
• Flow Fate: 0.5 gpm
(1.9 lpm)
General Installation/Operation/Maintenance
Requirements
Fhtsh
new
cartridge
al
fifll
flow
fi)r
S minutes
to
purge
out
lrapped
air.
Replace
cartridge
when
[low
becomes
too
slow.
Special Notices
• Installation
instruclions,
paris and service availability, and standard
warranty are included
with Ihe product
when shipped.
• This drinking
water system
InUSt be maintaiImd
accord'ng
to Inanufacturer
s "nstructions,
including
replacement
of filter
carlridges.
• Do IlOl use with water
lhat is microbiologically
unsafe
or of unknown
quality
withoul
adequale
disinfeclion
before
or
after the system. Systems certified for cyst reduction
may be used on disinfected
water Ihal may contain fiherable
cysls.
• The contaminants
or other substances
removed
or reduced
by lhis water lreatment
system are not necessarily in your
waler.
• Check for compliance
with the slale and local laws and regulations.
• Note that while the testing was performed
under slandard
laboratory
conditions,
actual performance
may vary. Systems
must be installed
and operated
in accordance
with manufacturer's
recoInInended
procedures
and guidelines.
S}_tem
Tested
and
Certified
by NSF International
against
ANSI/NSF
Stmtdard
42 & 53 for
the reduction
of:
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
Taste
and
Odor
Reduction
Chh)rine
Reduction
Mechanical
Filtration
Unit
Particulate
Reduction,
Class
I
Standard
No. 53: Health
Effects
Chemical
Reduction
Unit
Lead
arid An'azine
Reduction
IJndane
and
2,4-D
Reduction
Mechanical
Filtration
Unit
Tul bidity
Reduction
(?,_t mtd A_sbestos
Reductkm
Mmmiactured
for: General
Electric
Compan};
Eouisville,
KY 40225
40

Hide quick links:

Advertisement

loading