Electrical Requirements - GE JP328 Owner's Manual & Installation Instructions

Electric buil-in cooktop
Table of Contents

Advertisement

Installation instructions
ELECTRICAL REQUIREMENTS
A'I-FENTION:
All electric
cooktops
must
be hard
wired
(direct
wired)
into
an ai_provedjuncfion
box.
A plug
and
receptacle
is not pemfitted
fin" these
products.
We reconnnend
you
have
the
electrical
wiring
and
hookup
of your
cooktop
done
by a qualified
electrician,
_Mtei" installation,
have
the
elect[_cian
show
you
where
your
inain
disconnect
is located,
Check
with
your
local
utilities
fin" electrical
codes
which
apply'in
your
area.
Failure
to wire
your
cooktop
according
to governing
codes
could
result
ill a
hazardous
condition,
If there
are
no local
codes,
your
cooktop
II/USt be wired
and
fused
to ineet
the
requirelnents
of the
National
Electrical
Code,
ANSI/NFPA
No,
70 i,atest
Edition,
_m
can get
a copy
by writing:
National
[qre
Protection
_ssociation
gatter)anarch
Park
Quincy,
MA 02269
You
should
use a single
phase,
three
wire
240/120
Volt,
60 Hertz
electiical
power
s):smln.
If ahuninunl
wiring
is
used,
all connections
MUST
be lismd
fin" use with
ahnninunl
and
copper
wiring.
It is smmgly
reconnnended
that
if ahuninuln
wiring
is used,
the
special
ternfinal
grease
fin" use with
ahnninum
widng,
prefl_rably
with
"grit",
is put
into
the
connection
to keep
it ti'om
corroding
over
tim e.
At a nfimm
ran,
the
National
Electrical
Code
wire
sizing
ill Section
310 should
be fi)llowed.
It is fiu'ther
reconnnended
that
No. 8 AWG
copper
(or No.
6 AWG
ahuninum)
wire
or larger
if required,
protected
with
either
a double
pole
40 Alni)ere
drcuit
breaker
or t\_x_
4t) Mni)ere
fllses,
be used
to
supply
power
U_ the
cooktop.
See the
section
on Electrical
Connections
fin" detailed
insti uctions
on hookup
of your
cooktop.
PRODUCT
DiMENSiONS
AND CLEARANCES
This
cooktop
cannot
be
installed
ill countertops
that
cannot
accept
screws,
such
as granite
or inarble,
etc.
Counter
space
II/USt be provided
fl)r installation
of
the
cooktop.
To insure
accuracy,
it is best
to inake
a
telni)late
when
cutting
the
oi)ening
ill the
counter.
See
illustration
below
fi)r all necessary
dimensions.
When
choosing
a location,
the
fl_llowing
nfininmln
clearances
must
be maintained
between
the
cooktop
and
ac!jacent
Colnbustible
surtaces:
30"
(76.9
cm)
nfininmln
vertical
clearance
fl'oln
the
cooktop
to the
nearest
overhead
surtace.
15" (38.1
cln)
nfininmln
vertical
clearance
to
a(!jacent
cabinets.
15"
(38.1cm)
Min.
L Min.
clearanceto
side wall
Cooktop and cutout dimensions
A
B
C
D
E
F
G
Model
JP328
JP626
30¼"
357_"
76.8 cm
90.2 cm
211/4"
21"
54.0cle
53.3 cm
28W'
3311As"
72.1cm
85.6 cm
19_"
1815As"
49.2cm
48.1 cm
197/'
191/u"
49.5cm
48.6 cm
287/'
887/u"
72.4cm
86.0 cm
1474"
161%s"
36.2cm
43.0 cm
Model
JP328
JP626
H
3" lein.
3" lein.
7.6 cle
7.6cm
I
lY4" rain.
1W' rain.
4.4 cm
4.4cm
d
31//' rain.
21//' rain.
8.9 cm
6.4cm
K
2" min.
3SA " min.
5.1 cm
9.5cm
L
57/' rain.
83/4" r ain.
14.0cm
9.5cm
M
331/4"rain.
413_ " rain.
84.5 cm
105cm
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jp626

Table of Contents