Troubleshooting
Problem
Engine is running, but no AC
outputis available.
Engine runsgood at no-load
but "bogs down"when loads
are connected.
Enginewill not start; or starts
and runsrough.
Cause
1. One of the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
,
2.
3.
4.
5.
Short circuit in a connected load.
1.
Engine speed is too slow.
2.
Generator is overloaded.
3.
Shorted generator circuit.
4.
Clogged or dirty fuel filter.
5.
Correction
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Checkand repair.
4. Connect another device that is in good
condition.
Disconnect shorted electrical load.
Contact authorized service facility.
See Don't OverloadGenerator.
Contact authorized service facility.
Cleanor replacefuel filter.
1. Start switch in off (0) position.
2. Fuel valve is in "Off" position.
3. Failed battery.
4. Low oil level.
5. Dirty air cleaner.
6. Clogged or dirty fuel filter.
7. Out of fuel.
8. Stale fuel.
9. Spark plug wire not connectedto spark
1. Turn key in start switch to run (I).
2. Turn fuel valve to "On"position.
3. Replace battery.
4. Fill crankcase to proper level or place
generator on level surface.
5. Cleanor replaceair cleaner.
6. Cleanor replacefuel filter.
7. Fill fuel tank.
8. Drain fuel tank and carburetor; fill with
fresh fuel.
9. Connectwire to spark plug.
plug.
10. Bad spark plug.
11. Water in fuel.
12. Flooded.
10. Replace spark plug.
11. Drain fuel tank and carburetor; fill with
fresh fuel.
12. Wait 5 minutes and re-crank engine.
Engineshuts downwhen
running.
Engine lackspower.
Engine"hunts" or falters.
13.
14.
15.
1.
2.
3.
Excessively rich fuel mixture.
13.
Intake valve stuck open or closed.
14.
Engine has lost compression.
15.
Out of fuel.
1.
Clogged or dirty fuel filter.
2.
Low oil level.
3.
1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
1. Carburetor is running too rich or too lean.
2. Clogged or dirty fuel filter.
,
2.
3.
1.
2.
Contact authorized service facility.
Contact authorized service facility.
Contact authorized service facility.
Fill fuel tank.
Cleanor replacefuel filter.
Fill crankcase to proper level or place
generator on level surface.
See Don't OverloadGenerator.
Replace air filter.
Cleanor replacefuel filter.
Contact authorized service facility.
Cleanor replacefuel filter.
21