Performance Data Sheet - GE PDF22MFSABB Owner's Manual And Installation Instructions

Bottom freezers refrigerators models 20 and 22
Hide thumbs Also See for PDF22MFSABB:
Table of Contents

Advertisement

Performance Data Sheet
SmartWater
Filtration
System
GSWF Cartridge
This system has been tested according to NSF/ANS142/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142/53.*
(100% safety factors built in for unmetered usage)
Parmneter
(_hlorin<
T & ()
Parti< ulate '_':
USEPA
MCL
Int]uent
Average
1.845 mg/I.
143,3.3.3#imL
Effluent
Average
Maximmn
< 0.05 mgiI.
0.05 mgiI
29.83 #imI.
140 #imI.
% Reduction
Average
Minimmn
> _ 7 2( !'_
96.43%
Standard
No. 42: Aesthetic
Effects
hfl]uent Ch'_enge
Concentration
2.0 mgiI.+ 10%
at legist 10,(X)0 pmticlt_simL
Standard No. 53: HeMth Effects
Influent
Challenge
Effluent
99.98%
99.91%
Parmneter
USEPA
hrtluent
% Reduction
"[-u rbiditv
(X'sts
I.ead at pII 6.5
I.ead at pII 8.5
I.indane
Atrazine
Mha. Required
Reduction
> 50!_
> 85!_
Mill. Required
MCL
1 NTI ***
99.95!i P.c<luction
0.015 mgiL
0.015 mgiI
0.0002 mgiL
0.003 mgiL
Average
10.3 NTI 5***
2(_),(_)0 #iL
0.15 mgiL
0.14 mgiL
0.0216 mgiI.
0.008 mgiI.
Cozlceallralion
1+1 NTI ***
Minimum 50,000 L
0.15 mgiI.+10!_i
0.15 mg!L+10%
0.002 mgiI.+10!_i
0.009 mgiI.+l 0!_
Average
0.106 NT[ 7
0
< 0.001 mg!L
0.001 mgiI.
< 0.00002 mgiL
< 0.002 mgiL
Maxilll
ilnl
0.14 NTI
0
< 0.tR) l mgiL
0.003 mgiI.
< 0.00002 mgiL
< 0.1_)2 mgiL
Average
98.97!;i
> 99.99%
> 99.33%
> 99.29%
99.07!;;
> 76.12rN
Mi*firnmn
Reduction
98.61 !:_
0.5 NTI
> 99.99%
> 99.95%
> 99.33%
0.010 mgiL
97.86!::i
0.010 mgiL
98.751:i
0.(;002
mgiI
> 66.67%
0.003 mg!L
* Tested using a flow rate of O. 5 gpm; pressure of 60 psig; pH of 7.5 _+O, 5 ; temp, of 68 ° _+5°F (20 ° _+ 3°C)
** Measurement in Particles/ml. Particles used were 0,5-1 microns
* * * NTU=Nephelometric Turbidity units
Operating Specifications
(_apa('ity:
certified
ti)r
up to 750
gallons
(2,838
1); up to six months
Pressure
reqtfiremelm
40-120
psi
(2.8-8.2
bar)
TeI/lperattlre:
33-100°F
(0.6-38°C)
How
rate:
0.5 gpln
(1.9
lpln)
General Installation/Operation/Maintenance
Requirements
Flush
new
cartridge
at full
flow for
.3 milmtes
to I)ur("e_ out
trapped
air.
Replace
cartridge
when
flow becolnes
too
sh)w.
Special Notices
h_stallation
ii_sti uctions,
parts
aim
service
availability,
aim
standard
warranty
are
inchMed
with
the
product
when
shipped.
This
drinking
water
system
mtlst
be
inaintained
according
to illalltllhCttlrer's
instructions,
ii_cltMing
replacenlent
of filter
cartridges.
Do
not
use with
water
that
is microbioh)gically
tmsate
or of tmkI_own
quality
without
adequate
disilffection
betore
or
atier
the
svsteln.
Svstelns
certified
tot
cvst reductioi_
inav
be
used
on disintected
water
that
inav
contain
filterable
cysts.
The
COlmtndlmnts
or other
substances
relnoved
or redttced
bv this
water
treatn/ent
svsteln
are
not
necessarily
in wmr
water.
Check
tor
conq)liance
with
the
state
aim
local
laws aim
regtdations.
Note
that
while
the
testing
was pertimned
trader
standard
laboratory
conditioi_s,
actual
perfornmnce
inay
wtrv.
Svstelns
inust
be
installed
aim
operated
in accordance
with
inanuthcturer's
recomlnelMed
procedures
and
gtfidelines.
System tested and certified
bv NSF International
against Standard 42 for tile reduction
of
chlorine,
taste and odol; par{iculat_
Class I and Standard
53 ti)l- the retluction
of cyst,
lead, I.indane,
Atrazine
and mrbidily.
ManuL,ctured
fi)r: General
Electric Compan 5 I.oui_ville, EY 40225
4/

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents