GE Monogram ZISS360DXBSS Owner's Manual page 27

Side-by-side 36", 42", 48" built-ln refrigerators
Hide thumbs Also See for Monogram ZISS360DXBSS:
Table of Contents

Advertisement

Performance
Data Sheet
SmartWater Filtration System
MWF Cartridge
This sgstem has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
USEPA
Influent
Parameter
MCL
Challenge Concentration
Chlorine
-
2.0mg/L± 10%
T&O
-
-
Particulate**
-
_> 10,000particles/mL
Standard No. 42: Aesthetic Effects
Influent
Effluent
Average
Average
Maximum
1.96mg/L
0.06mg/L
0.11mg/L
6,400,000 #/mL
58,833#/mL
150,000 #/mL
% Reduction
Average
Minimum
96,77%
94,74%
99.14%
97,97%
Min. Required
Reduction
> 50%
_> 85%
Parameter
Turbiditg
Cgsts
Asbestos
Leadat pH6.5
Leadat pH8.5
Mercurgat pH6.5
Mercurgat pH8.5
A1Gchlor
LindGne
2,4-D
Toxophene
Benzene
Corbofuron
1,4 dichlorobenzene
Atrozine
USEPA
MCL
0.5 NTU
_> 99.95% Reduction
_> 99%Reduction
0.015mg/L
0.015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.040mg/L
0.075mg/L
0.003mg/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11+ 1 NTU***
Minimum50,000L
107to 108fibers/L; > 101Jm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
10.5NTU
118,750 #/L
57 MF/L
0.1567mg/L
0.1433mg/L
0.0059mg/L
0.0057mg/L
0.0367mg/L
0.0020mg/L
0.2033mg/L
0.0160mg/L
0.0145mg/L
0.0830mg/L
0.2283mg/L
0.0087mg/L
Effluent
Average
0,14NTU
< i #/L
0,996MF/L
< 0,001mg/L
< 0,001mg/L
0.000350 mg/L
0.000325 mg/L
0.00023 mg/L
< 0.00002 mg/L
0.00337 mg/L
0.00100 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
Maximum
0.28NTU
4#/L
< 1 MF/L
<0,001mg/L
<0.001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
< 0.00002 mg/L
0.011000 mg/L
0.001000 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
% Reduction
Average
Minimum
98,54%
9720%
> 99,99%
> 99,99%
%60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
96.51%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93,33%
Min. Required
Reduction
0.5 NTU
2 99.95%
_> 99%
0.010mg/L
0,010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0,04mg/L
0.075mg/L
0.003mg/L
Tested using a flow rate of 0.50 gpm; pressure
of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° +_5°F (20 ° +_3°C1
** Measurement
in Partictes/mt.
Particles used were 0.5-1 microns
*** NTU=Nephetometric
Turbiditg
units
Operating
Specifications
• Capacity: certified for up to 300 gallons (1135 I); up to one year
• Pressure requirement:
40-120
psi (2.8-8.2 bar), non-shock
• Temperature:
33-100°F
(0.6-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
• Flush new cartridge
at full flow for 5 minutes to purge out trapped
air.
• Replace cartridge
when the indicator
light flashes.
Special Notices
• Installation
instructions,
parts and service availabilitg,
and standard
warrantg
are included with the product when shipped.
• This drinking water sgstem must be maintained
according to manufacturer's
instructions, including replacement
of filter cartridges.
• Do not use with water that is microbiologicallg
unsafe or of unknown
qualitg without
adequate
disinfection
before or
after the sgstem. Sgstems certified
for cgst reduction
mag be used on disinfected
water that mag contain filterable
cgsts.
IThe
contaminants
or other substances
removed
or reduced bg this water treatment
sgstem are not necessarilg
in gour water.
• Check for compliance
with the state and local laws and regulations.
• Note that while the testing was performed
under standard
laboratorg
conditions,
actual
performance
mag varg. Sgstems must be
installed and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
Chlorine
Taste and Odor
Mechanical
Filtration
Unit
Particulate
Reduction,
Class I
Sgstem Tested and Certified bg NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercurg and Toxaphene Reduction
Mechanical Filtration Unit
Turbiditg Reduction
Cast and Asbestos Reduction
Manufactured
for: General
Electric
Compang,
Louisville,
KY 40225
EPA EST. No. 070595-MN-001
27