GE GXSF40H Owner's Manual & Installation Instructions page 23

Water softening system
Table of Contents

Advertisement

Available languages

Available languages

ge.com
Problem
Saltg tasting or
brown/gellow colored
water after installation
Brown/yellow
colored water
Resin beads showing
up in drinking water
and sink
Possible
Causes
Unit not sanitized
What To Do
• Complete the Sanitizotion procedures on page !3.
• At completion of rechQrgecycle (Qpprox.2 hrs),run water
from faucets to purge the sQItywater.
Low water pressure
Check pressure.
• DrQinheight 8' or less,pressure should be minimum of 20 psi.
• DrQinheight above 8', pressureshould be minimum of 50 psi.
Restricted drain hose
• Cleon and reconnect hose.
• Check for kinks in drain line.
Unit was idle for a period of time
• Complete the Sanitizotion Procedureson pQge15.
Cracked distributor
• Coilfor service.
Sounds gou might hear
Running water from the unit
• This is normal.
into a drain during recharge
Water has air bubbles
Air in sgstem after installation
• Will go away after it runs for a while.
and is cloudg
Error Code on control
Wiring meg have worked loose
in the control
• See pQge 17 for details.
• Unplug transformer.
• Removecontrol cover,releQseclips on side.
• Check for loose/incorrect wiring connections to electronic
boQrd or switch. Reconnect as required.
• ReQssemble control cover.
• Plug in Transformer.
• Wait six minutes for Error Codeto reQppeQr.
• If Error Code reQppeQrs, c all for service.
Blue light flashing
When power applied
Control needs to be programmed
• See the Progromming the Contro! section, pQge lO.
to the sgstem
(a power outage mag have occurred}
If"DAYS TO EMPTY"
Low salt level, less than 15 dags
• Fillwith sQIt.
is flashing
• Reset sQIt level.
If"Err" in display
Electrical problem with sgstem
• See pQge 17 for details.
• See procedure above, Error code on control.
23