NO SOFTWATER - Most Common Problems:
Check the following before calling for service:
• Not enough salt-should be at least 1/3 full.
Bypass valve in "Bypass" position-knob should be in the "OUT"(service)position.
Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply
waterifrom
local water company, water test or call the GE Answer Center.
Salt Bridge-salt solidifies above water level so that brine water is not in contact with
salt. See the Breaking a Salt Bridge section.
Problem
Possible Causes
What To Do
No soft water
Faucet or fixture where sample was
taken not plumbed to soft water.
NOTE:Be sure sample is from a faucet
that does not mix soft and hard water.
For example, a single lever kitchen faucet,
if the cold side is plumbed to hard water.
• Toconserve salt, the installer mag have isolated some fixtures
(outside faucets, toilets, etc.)from soft water. From the outlet
of the water softening system, trace the water flow path,
in house plumbing. If soft water is not directed to a faucet
or fixture where wanted, consult a plumber.
No salt in the brine tank or
salt bridged
Check for a salt bridge or, if the tank is emptg, refill with
recommended salt. Press(for 3 seconds)the RECHARGE@
button to start an immediate recharge and restore
soft water supplg.
Transformer unplugged at wall outlet or
power ca ble to softener not connected.
Fuse blown or dmuit breaker popped
on cimuit to electrical outlet.
Electrical outlet on a cimuit that can
continuouslg
be switched off
Check for a loss of electrical power to the water softening
sgstem, due to ang of these conditions and correct as needed.
With the power supplg restored, observe the faceplate time
displag and read programming the Contro! section.
NOTE:Theelectrica!outlet for the softener should be
liveso it cannot be accidenta!lg switched off.
Manualbgpassvalve in bgpassposition • Be sure the bgpass valve stem is positioned properlg, with the
knob in the OUTposition. Observeinstructions on the decal
at the end of the stem.
Valve drain hose pinched, plugged,
elevated too high or otherwise
restricted
• Any restriction in this drain hose mag prevent proper
operation of the nozzle and venturi and reduce or prevent
brine draw during recharge.
Nozzle and venturi dirtg, incorrectlg
assembled
or damaged
Refer to Cleaning the Nozzle and VenturiAssembly instructions.
With water pressureto the water softening sgstem off, take the
nozzle assemblg apart. Inspect, clean and replace as needed.
Ang foreign particle(s),scratches, nicks, etc., in the passages can
prevent operation. Besure holesin the gasket are centered over
holes in the housing.