Installation and Assembly - CRT Ceiling Mount Kit for 14" - 17" Monitors
IMPORTANT!
Read entire instruction sheet before you
start installation and assembly.
IMPORTANT!
This kit includes all mounting hardware
for direct attachment to a wood joist ceiling. For
concrete ceiling installations order accessory kit ACC
210. Fixed Length and adjustable extension columns
are also available.
Before you start make sure all of the parts shown below are included with your product.
A
C
B
J
L
N
Visit the Peerless Web Site at www.peerlessindustries.com
E
F
D
K
O
• Installer must verify that the ceiling will safely support
four times the combined weight of all attached equip-
ment and hardware.
H
G
PARTS LIST
PART #
A 530-9413
B 540-9440
C 520-9513
D 520-9549
E 540-9406
F 540-9405
G 520-9250
H 520-9210
I
530-9306
J 073-1007
K 073-1008
L 073-1001
M 073-1002
M
N 073-1003
O 073-1004
P 128-1039
Q 2PT-22CA01D
R 1446-014
S 1800-375
T 540-9432
U 5S1-015-C03
Note: Parts may not appear exactly as illustrated.
Q
P
1 of 5
For customer service call 1-800-729-0307 or 708-865-8870.
Model: IMC 18
WARNING
I
U
QTY.
DESCRIPTION
4
1/4-20 nylock nut
4
1/4 SAE flat washer
4
1/4-20 x 3/4" carriage bolt
6
5/16-18 socket head screw
8
5/16 SAE flat washer
6
5/16 lock washer
5
M5 x .8 x 10 mm phillips screw
2
5/16-18 x 3/4" hex head bolt
2
5/16-18 nylock nut
1
hanging bracket
1
tilt bracket
1
left adjuster
1
right adjuster
1
left tray
1
right tray
1
ceiling plate
2
ceiling plate end cap
1
flush mount tube
1
retaining collar
1
fiber washer
4
#14 x 2.5" (6 mm x 65 mm)
wood screw
T
S
ISSUED: 2-19-98 SHEET #: 073-9003-1
R
08-26-04

Advertisement

loading

Summary of Contents for PEERLESS IMC 18

  • Page 1 Installation and Assembly - CRT Ceiling Mount Kit for 14" - 17" Monitors Model: IMC 18 IMPORTANT! Read entire instruction sheet before you WARNING start installation and assembly. IMPORTANT! This kit includes all mounting hardware for direct attachment to a wood joist ceiling. For •...
  • Page 2 From the top thread flush mount tube (R) through threaded fitting in ceiling plate (P). IMPORTANT: If you will install an extension column DO NOT INSTALL THE FLUSH MOUNT TUBE. For Wood Joist Finished Ceiling, Ex- posed Wood Joists, or Wood Beam Ceiling.
  • Page 3: Cutaway View

    WARNING • Installer must verify that the ceiling will safely support four times the combined weight of all attached equip- ment and hardware. 5/16" (8 mm) For Concrete Ceilings drill four 5/16" (8 mm) dia. holes to a minimum depth of 1 3/4" (45 mm).
  • Page 4 First: Assemble bracket as shown. Leave all fasteners slightly loose to allow for adjustment. Second: From behind, insert monitor into bracket. Face of monitor should touch returns on left and right trays (N & O). Adjust height and width of bracket to fit snugly around monitor.
  • Page 5 For customer service call 1-800-729-0307 or 708-865-8870. Visit the Peerless Web Site at www.peerlessindustries.com © 2004 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark of Peerless Industries, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners.