Pressure Transducer Seal
Installation
1. Lightly coat cleaned packing recess in manifold
with a light grease or oil.
2. Heat seal (69) in hot water for several minutes.
CAUTION
Excess pressure from the probes or fingernails will
damage the packing and cause subsequent leakage.
3. Use a blunt wooden or plastic probe and install
seal (69) into recess in manifold (229). Be careful
not to cause kinks or bends in packing during
installation.
4. Lightly grease or oil transducer (67) and install
pump (18). See page 11.
Fig. 16
69
229
9666A
309067