Performance Data Sheet - GE Profile PSF26NGPCBB Owner's Manual And Installation

Models 23, 25, 26, 27 and 29
Table of Contents

Advertisement

Available languages

Available languages

Performance Data Sheet
SmartWater
Filtration
System
MWF
Cartridge
This system has been testedaccording to NSF/ANS142/53 for reduction of the substanceslistedbelow.
The concentration of the indicated substances in water enteringthe system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142/53.*
'100%safety factors built in for unmetered usage)
Parameter
USEPA
M(%
USEPA
MC%
0.5 N'F_
Chlorine
T&O
Paniculat_ **
Parameter
"Ihrbkliw
C_ms
_> 99.!)5% Rt (htcd,.m
X_bestos
_> 9!)% Rcducti,.m
[ _ead at p} i 6.5
0.0] 5 mg/L
I _ead at pl { 8.5
0.0] 5 mg/L
,\lert mw nl pH 6.5
0.IX)2 mg/L
Mort ur} m pit 8.5
0.1_)2 mg/L
Aladfi0r
0.002 mg/L
I .indane
().()(_)2 mg/I,
2,_D
0.070 mg,/I,
qbxaphene
0.(X)3 rag/l,
Benz( ne
0.(_)5 mg/L
Cafl)ofimm
0.040 mg/L
1,4 dkhl0r0benzene
0.075 mg/L
Au'a/ine
0.003 mg/L
]Jt_H#lli
Challenge Concentralion
2.0 rag/I, +_]0%
_>10,000 partM(s/nfl.
Stmldard
No. 42: Aesthetic
Effects
Influent
Effluent
Average
Average
Maximmn
] .96 mg/I_
0.06 mg/L
0.1 ] mg/L
6,400,000 #/mL
58,833 #/mL
] 50,000 #/ml.
Standard
No. 53: Health
Effects
[r_luent
Challenge
Concentration
] ] + ] NT[ *'::*
Minimum 50,IX)0 L
] 07 to ] 0s fibers/[; > ] (tirol
0.] 5 mg/I, + 10%
0.15 mg/L +_10%
0.006 mg/L + 10%
0.006 mg/L + 10%
0.04 mg/L + ]0%
0.002 mg/L + 10%
0.2] 0 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
O.OS) mg/L + 10%
0225 mg/L + ]0%
0.009 mg/L + ]0%
hffluent
Average
] 0.5 NT[
]] 8,750 #/I+
57 MF/I+
0.] 567 rag/l+
0.1433 rag/I,
0.0059 rag/I,
0.0057 rag/I,
0.0367 rag/I,
0.0020 rag/I,
02033 rag/I,
0.0](_0rag/I,
0.0] 45 rag/I,
0.0830 rag/I,
02283 mg/L
0.0087 mg/L
Effluent
Average
Maximum
0.14 NT[
028 NT[
< ] #/1.
4 #/1.
0.996 MF/L
< ] MF/L
< 0.00] mg/L
< (1.(t0] mg/L
< 0.001 mg/L
< 0.(}0] mg/L
0.000350 mg/L
0.0007 rag/I,
0.000325 mg/L
0.000(i rag/I,
0.00023 mg/L
0.0004 rag/I,
< 0.00IX)2 mg/I,
< 0.0(XX)2mg/L
0.00337 mg/L
0.011000 rig/I,
0.00100 mg/L
0.001000 rig/I,
0.000500 mg/L
0.000500 rag/I,
0.001000 mg/L
0.001000 rig/I,
0.000500 mg/L
0.000500 mg/L
< 0.0005 rag/l,
< 0.0005 mg/L
% Reducllon
Average
Minimum
96.77%
94.74%
9!).14%
!)7.97%
% Redut_ion
Average
Minimum
98.54%
97.20%
> 9!).!)9%
> 9!).!)9%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95!_
98.32%
94.5()!_
93.44%
91 .(17!_
96.5] %
95.83!i
98.78%
98.(i5!_
99.78%
99.77!_
94.22%
93.33!_
Min. Required
Reduction
> 50%
_> 85%
Min. Required
Reduction
0.5 NT(
_> 99.95%
_> 99%
0.0] 0 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.04 rag/I,
0.075 mg/L
0.003 mg/L
Tested usbg a f/ow rate of O.5O gpm; pressure of GOpsig pH of 7.5_+0.5; temp. of 68°_+ 5°F120°_+3°C)
++ Measurement in Partic/es/m/. Partic/es used were 0.5-1 microns
.... NTU=Nephe/ometric Turbidity units
Operating Specifications
[] Capacit?
: certified
hw
up to 300 gallons
(I 1371 1); up to six months
fi)r models
_dthout
a replacement
filter
indicator
light;
up to one
?ear
fi)r models
with
a replacement
filter
indicator
light
[] Pressm'e
requirement:
40-120
psi
(2.8-8.2
bar),
non-shock
[] Temperature:
33-1
00°F
(0.6-38°C)
[] Flow
rate:
0.5 gpFa
(1.9
1pro)
General Installation/Operation/Maintenance
Requirements
[] Flush
new
cartridge
at hd]
fl()_
for
3 mim_tes
to pm'ge
out
trapped
air.
[] Replace
cartridoe, _
when
the
indicator
light
flashes
or water
flow
rate
is reduced
on non-indicator
units.
Special Notices
[] Installation
instructions,
parts
and
service
availabilit_
and
standard
_arrant}
are
included
_dth
the
product
when
shipped.
[] This
dfinldng
water
s}stem
must
be maintained
according
to mamdactmer's
instructions,
including
replacement
of filter
cartridges+
[] Do
not
use with
water
that
is microbiological]}
unsafe
or of unkno_n
qualit)
without
adequate
disinfection
before
or
after
the
svstem.
Sxstems
ceilified
for
Qst
reductioi_
max
be
used
on
disinfected
water
that
me}
contain
filterable
c}sts.
[] The
contaminants
or other
substances
removed
or reduced
b} this water
treatment
s}stem
are
not
necessafi]}
in )our
water.
[] Check
for
compliance
with
the
state
and
local
laws and
regulations.
[] Note
that
while
the
testiw*, _ *_as performed
under
standard
laboratory,
conditions,
actual
performance
max
varx.
S_stems
must
be installed
and
operated
in accordance
with
manufiicturer's
recommended
procedm'es
and
guidelines.
Stmldard
No. 42: Aesthetic
Effects
Chemical
l nit
Chlorinc
Taste
and
Odor
Mechanical
Filtration
Unit
Particulat_
Reduction,
Class
I
System
Tested
and
Certified
by NSF Int(
rnational
against
ANSIiNSF
Standard
42 & 53 fol- tile
reduction
of:
Standard
No.
53: Health
Effects
Chemical
Reduction
[nit
+Machlor and
Atrazine
Reduction
Benzene
and
Carbotman
Reduction
1,4 dichlorobenzene
and
2,44)
Reduction
Lead
and
I.indane
Reduction
Merctny
and
'Ibxaphene
Reduction
Mechanical
Fihration
1 nit
Turbidity
Reduction
Cyst and
Asbestos
Reduction
Manufactuled
tor:
(;eneral
Electric
Colnpall3,
Louisville,
KY 40225
EPA EST
No. 07(1595-MN-001
4/

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents